Clearaudio Version-1.4_12_03_08_E Ovation, left trimmer = setting 33 1/3 rpm, Please note

Models: Version-1.4_12_03_08_E

1 16
Download 16 pages 54.75 Kb
Page 12
Image 12
- left trimmer = setting 33 1/3 rpm

Ovation

User manual

On the rear (close to power supply input) of your turntable there are three setting trimmers:

- left trimmer = setting 33 1/3 rpm

(near tonearm)

- middle trimmer = setting 45 rpm - right trimmer = setting 78 rpm

Pic. 12: Fine speed adjustment

If you need to adjust the speed 33 1/3 rpm , take the aluminium screw driver (see accessories) and turn the left trimmer until you have reached the correct speed according to the Stroboscope Testrecord (see user manual “Stroboscope Testrecord”).

-

-

Turning the trimmer counter clockwise = reduces the turntable speed Turning the trimmer clockwise = raises the turntable speed

Use the same procedure to adjust the speed for 45 rpm and 78 rpm.

Please note:

If the turntable does not reach the correct speed, the sensor or the scale ring could be dirty or dusty.

To clean the sensor, very carefully lift off the two platters.

Clean the sensor and the scale ring with a little isopropyl alcohol and a cotton bud. Be extremely careful to avoid any scratches on the sensor or the scale ring!

If the motor still has speed variations please contact your nearest authorized clearaudio dealer or the clearaudio factory direct.

Now you are ready to play your vinyl records.

We wish you a lot of pleasure with your new Ovation - turntable.

Page 12

clearaudio electronic GmbH 2012

Page 12