Cleveland Range 36-CEM-16-48 Water Quality Requirement, Electric, Water C, Drainage, Clearance

Models: 36-CEM-16-48

1 2
Download 2 pages 51.41 Kb
Page 2
Image 2
ELECTRIC

ELECTRIC WATER QUALITY REQUIREMENT

KW

Volts

Watts

Ph

Amps

Wire

48

208

42,900

3

119.2

3

 

220

48,000

3

126.1

3

 

240

48,000

3

115.6

3

 

440

40,300

3

52.9

3

 

480

48,000

3

57.8

3

 

600

48,000

3

46.2

3

 

360

42,900

3

68.9

4

 

380

48,000

3

73.0

4

 

415

48,000

3

66.9

4

Each compartment has capacity for:

Eight, 12˝ x 20˝ x 212˝ deep Cafeteria Pans. Can accomodate 18˝ x 26˝ Bun Pans.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with those codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL, and others.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

 

WATER C

DRAINAGE

 

 

CLEARANCE

 

D

 

 

 

 

 

 

 

 

Cold Water Inlet

The Floor Drain must be located

Right - 3”, Left - 3”,

35 psi minimum

outside the confines of the

Rear - 3” (12” on control

60 psi maximum

equipment base.

side if adjoining wall or

 

 

1/4˝ NPT

1 1/2˝ I.P.S. common drain.

equipment is over 30” high

 

 

 

 

for service access)

 

 

Condenser feed

 

 

 

 

 

 

 

 

 

 

 

3/8˝ NPT Boiler

Do not connect other units to this drain.

Contact factory for

 

 

feed

Do not use PVC pipe for drain.

variances to clearances.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA.

(NOT TO SCALE) SECT. III PAGE 26 0707

Litho in U.S.A

Page 2
Image 2