Each compartment has capacity for:
Eight, 1 2˝ x 20˝ x 2 1⁄ ˝ deep Cafeteria Pans. Can
• accomodate 18˝ x 26˝ Bun2 Pans.
WATER QUALITY REQUIREMENT | |
The r ecommended m inimum water quality standards | |
whether untreated or | |
use per day, and a Daily Blowdown, are as follows: | |
TOTAL DISSOLVED SOLIDS | less than 60 parts per million |
TOTAL ALKALINITY | less than 20 parts per million |
SILICA | less than 13 parts per million |
pH FACTOR | greater than 7.5 |
CHLORINE | less than 30 parts per million |
Consult a local water treatment specialist for an on site | |
water analysis for recommendations co ncerning steam | |
generator feed water treatment (if required), in order to | |
remove or reduce harmful concentrations of minerals. The | |
use of highly mineralized wa ter will m ean t hat m ore | |
frequent ser vicing o f th | e ste am g enerator wil l b e |
necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
**Do not connect to GFI outlet. See note below.
Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining wall or equipment is over 30” high for service access)
For use in non- combustible locations. Contact factory for
Do not use PVC pipe for drain. variances to clearances
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibil ity of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are A SME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
(NOTIII TO SCALE)28
SECT. PAGE1007
Litho in U.S.A