| SPECIFICATIONS | |
|
|
|
|
|
|
|
|
|
|
|
|
MODEL NUMBER |
| |
|
|
|
MODEL RATING VA/W |
| 5000 / 3750 |
|
|
|
DIMENSIONS: inches (mm) |
|
|
|
|
|
Unit: W x D x H |
| 16.1 x 23.6 x 5.1(410 x 600 x 130) |
|
|
|
Shipping: W x D x H |
| 23.2 x 31.1 x 12.8 (590 x 790 x 325) |
|
|
|
WEIGHT: lbs (kg) |
|
|
|
|
|
Unit |
| 41.2 (18.7) |
|
|
|
Shipping |
| 53.8 (24.4) |
|
|
|
INPUT AC PARAMETERS |
|
|
|
|
|
Voltage Range |
| 208 VAC Nominal: |
|
|
|
Frequency |
| 50/60 Hz, ±5%; Auto Sensing |
|
|
|
Input Power Cord |
| 10 ft. attached, w/ NEMA |
|
|
|
OUTPUT AC PARAMETERS |
|
|
|
|
|
Output Receptacles |
| |
|
|
|
Voltage |
| 208 VAC, ±3% |
|
|
|
Frequency |
| 50 Hz or 60 Hz |
|
|
|
Waveform |
| Sinewave |
|
|
|
Main Mode Overload |
| 151 - 300% for 2 seconds; |
|
| 126 - 150% for 10 seconds; |
|
| 105 - 125% for 60 seconds with transfer to bypass |
DC INPUT PARAMETERS |
|
|
|
|
|
Voltage |
| 240 VDC Nominal |
|
|
|
Recharge Time |
| 8 Hours to 90% capacity after full discharge into 100% load |
|
|
|
ENVIRONMENTAL |
|
|
|
|
|
Operating Temperature |
| +32°F to +104°F (0°C to +40°C) |
|
|
|
Storage Temperature |
| +5°F to +122°F |
|
|
|
Relative Humidity |
| 0% to 95%, |
|
|
|
Operating Elevation |
| Up to 10,000 ft. (3000 m) at 104°F (40°C) without derating |
|
|
|
Storage Elevation |
| 50,000 ft. (15,000 m) maximum |
|
|
|
Audible Noise |
| < 55 dBA |
|
|
|
AGENCY |
|
|
|
|
|
Safety |
| UL 1778, |
|
|
|
RFI/EMI |
| FCC Part 15, Subpart B, Class A |
|
|
|
Transportation |
| ISTA Procedure 1A |
|
|
|
24