Specification Drawing -
Stationary, KGL-40, KGL-60, KGL-80, KGL-100NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.
1/2" dia.Soft
Copper Tubing
(each)
When ordered
with optional
faucet.
WATERELECTRIC
120V-1 Phase, 60 Hz, 10
amps
GAS CLEARANCE
H
RIGHT = 3"
LEFT = 3"
REAR = 3"
Allow 6" space minimum
from rear and sides when
located near combustible
walls.12" recommended on
right side for service
NATURAL PROPANE
Piping:3/4" N.P.T. Piping:3/4" N.P.T.
Supply pressure: Supply pressure:
4.00" W.C.minimum 4.00" W.C.minimum
14.00" W.C.maximum 14.00" W.C.maximum
Manufacturer must be notified if unit will be operated above 2,000 ft.altitude.
C
H
C
B.T.U.RATING
40 gal. 140,000
60 gal.
80 gal. 190,000
100 gal.
DIMENSIONSGALS./
LITERS ABCDEFGHJ KLMNOPST I.D.
40 IN 35 1/8 37 32 1/4 40 1/2 9 1/4 16 71 1/2 9 9/16 17 3/4
25 15/16
10 3/8 18 5/8 26 7/8 28 1/2 4 5/8 24 1/2 26
150 mm 893 940 820 1029 235 407 1817 243 451 659 264 474 683 724 118 648 661
60 IN 38 1/4 39 34 1/4 43 1/2 8 3/4 14 1/4 75 8 15/16 19 1/8 29 5/16 10 3/8 18 5/8 27 7/8 30 1/4 5 1/4 27 29 1/2
225 mm 972 991 870 1105 223 362 1905 228 486 745 264 474 709 769 134 686 750
80 IN 41 5/8 42 3/8 35 1/2 45 1/2 8 3/4 15 1/2 79 9 1/4 20 3/4 32 1/4 10 3/8 18 5/8 29 5/8 31 1/2 6 5/8 29 33
300 mm 1058 1077 902 1156 223 394 2007 235 528 820 264 474 753 801 169 737 839
100 IN 44 43 1/2 36 1/2 47 1/2 8 3/4 15 1/2 83 1/2 9 1/8 21 7/8 34 5/8 10 3/8 18 5/8 31 1/4 32 1/2 7 1/2 30 1/2 35 1/2
375 mm 1118 1105 928 1207 22.3 394 2121 232 556 880 264 474 794 826 191 775 902
G
(COVER
OPEN)
3" (77
mm)
MINIMUM
CLEARANCE
F
3 (77
mm)
L
M
N
O
P
H
J
K
FLOOR DRAIN
12" (305
mm) WIDE x
12" (305
mm) LONG
UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE,
SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.
75ยบ