Cleveland Range OGB-10.20 Saves energy Automatic moisture level adjustment, Front View, Top View

Models: OGB-10.20

1 2
Download 2 pages 7.81 Kb
Page 2
Image 2
FRONT VIEW

 

 

 

47.92"

 

 

2.52"

1.58"

1.82"

 

 

 

 

44.98"

 

38.98"

 

 

 

6.00"

 

 

 

 

 

 

FRONT VIEW

7.49"

3.55"

3.39"

 

 

13.07"

 

 

 

AV

 

 

 

 

40.44"

 

 

 

E2

 

 

 

E1

 

 

 

 

 

 

 

 

S

 

 

2.80"

 

 

 

 

 

 

TOP VIEW

 

 

2.80"

 

 

 

 

8.55"

 

 

 

 

12.68"

 

31.50"

The "Advanced Closed System" offers the following advantages:

Saves energy

Automatic moisture level adjustment

Low heat and steam emission to the kitchen

Automatically regulated steam injection

Enables immediate change into the steam mode

"Crisp & Tasty" demoisturizing function

Model:OGB-10.20

Pan Capacity [Unit has 11 slide rails at 2.64" (67mm) apart]:

11

(20" x 26") full size wire racks

11

(18" x 26") full size sheet pans - on wire racks

22

(13" x 18") half size sheet pans - on wire racks

20

(12" x 20" x 2 1/2") steam table pans

22

(12" x 20" x 1") steam table pans

20

(12" x 20") frying baskets - (no wire racks needed)

 

 

 

 

For Banquet Operations: Optional Plate Rack holds 63 plates

Unit Dimensions: Width - 52.26", Depth - 43.24", Height - 45.68"

Shipping Dimensions: Width - 58", Depth - 49", Height - 54" (including packaging)

Shipping Weight:

540 Lbs

 

 

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Agency Approvals: UL - Gas, UL - Sanitation (NSF Standards)

Electrical Requirements: 120 volt, 15.9 amps, 60 Hz, single phase Do not connect to a G.F.I. outlet

 

Gas Connection:

3/4" NPT

G Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

Total Connected Load:

132,700 BTU (119,000 BTU Propane)

 

Steam Generator:

113,600 BTU (102,000 BTU Propane)

 

Hot Air:

132,700 BTU (119,000 BTU Propane)

 

 

 

 

 

 

3.23"

41.42"

3.27"

 

Water Connections:

Cold Water (drinking water quality)

 

 

 

 

 

 

 

Flow Pressure:

30 - 60 PSI

 

 

 

10.40"

 

6.93"

 

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

27.29"

21.19"

14.26"

 

 

 

 

 

 

 

W1

Treated Water for Steam Generator

 

 

 

 

 

 

 

 

 

 

 

G

 

 

W2

Untreated Water for Condenser and Hand Shower

 

2.96"

 

 

D

29.61"

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

W1

 

 

1.19"

 

 

 

 

 

 

 

RC

 

 

W2

 

 

E1

Gas Exhaust for Hot Air Heating

 

 

 

 

 

 

 

 

3.90"

 

 

 

 

 

 

 

 

 

E2

Gas Exhaust for Steam Generator

 

 

 

 

 

 

 

 

CS

 

 

 

 

 

AV

Air Vent

 

 

 

3.00"

BOTTOM VIEW

 

 

 

 

 

4.97"

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

10.87"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.

S Low Pressure Safety Valve

*Available as an option

SECT. IIA PAGE010824

 

Page 2
Image 2
Cleveland Range OGB-10.20 Saves energy Automatic moisture level adjustment, Low heat and steam emission to the kitchen