SPEED SELECTION

The machine is equipped with two speed ranges, High, and Low, and a stepless variation of each range.

The speed range is changed by the rotary change switch located on the gearbox side. Do not change gear while the motor is in motion.

The stepless variation is adjusted by rotating the disk located on top of the motor. The disk is graduated into six numerically designated segments.

Before cutting holes the work piece material specification must be determined to facilitate the correct cutting speed selection (See section 13 Cutting speeds). Site conditions, eg diameter and condition of cutter, material condition, material thickness, etc must also be taken into account when determining the suitable cutting speed. The speed and feed rate must continuously be monitored and adjusted to ensure optimum cutting conditions prevail.

[4]EXTENSION CABLE SELECTION

The machines are factory fitted with a 3 metre length of cable having three conductors 1.5mm_

LIVE, NEUTRAL and EARTH. If it becomes necessary to fit an extension cable from the power source, care must be taken in using a cable of adequate capacity. Failure to do so will result in a loss of traction by the magnet and a reduction of power from the motor.

Assuming a normal AC supply of the correct voltage, it is recommended that the following extension lengths shall not be exceeded:

For 110v supply:

3.5metres of 3 core x 1.5mm_

For 230v supply:

26metres of 3 core x 1.5mm_ or

 

17metres of 3 core x 1.0mm_

ALWAYS DISCONNECT THE MACHINE FROM THE POWER SOURCE WHEN CHANGING CUTTERS.

[5]MOUNTING OF CUTTERS

The machine has been made to accept cutters having 19.05mm (3/4") dia. shanks

The following procedure is to be used when mounting cutters.

Take appropriate pilot and place through hole in shank of cutter. Insert shank of cutter into 3/4" dia. bore of arbor, ensuring alignment of two drive flats with socket screws RD4066. Tighten both screws using hexagon key.