The power and protection indicators include a green Greenlight, a redLightlight and an alarm.
RedPowerLighton – Theand/orgreenAlarmight should remain on steady. Current overload – The red light will blink continuously, then the inverter will shutdown. The inverter will continue to check for appropriate current levels while trying to restart the load.
DC input voltage overload – The red light will turn on and the inverter will shutdown. The inverter will continue to check for appropriate voltage levels while trying to restart the load.
DC input voltage shortage – As a warning that the voltage is getting low, the internal alarm will sound. When the voltage is too low, the inverter will shutdown and the red light will turn on. The inverter will continue to check for appropriate voltage levels while trying to restart the load.
Temperature overload – The red light will blink, then the inverter will shutdown. The inverter will continue to check for appropriate temperature levels while trying to restart the load.
NOTE A momentary sound of the internal alarm and/or flash of the red light is normal at start up.
Operation | Operating Limits | • |
Power Output |
| |
Operating Limits |
|
The inverter can deliver 400 watts for about 60 minutes. The inverter must cool for 15 minutes before it can resume operation at 400 watts. Note: The wattage rating applies to resistive loads.
The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other
The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 10.5V+/- 0.3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below
The inverter will also shut down if the input voltage exceeds