To check your inverter’s performance before installation:

Quick Evaluation

as well.Installation Before Installation

Introduction

Test Load￿A test load that can InstallationRequirementsbe plugged into the AC receptacle on the inverter A. Dry for short term testing at a low power level.

To check your inverter’s performance before installation:

On/OffSwitchto Off

1. Turnthe inverteroff (see page 11

 

for details).If the power sourceis

 

a DC power supply,switch it off

 

as well.

Installation

Requirements

Installation

InstallationRequirements

The inverter must be installed in an area that meets all of the following requirements:

A. Dry

Do not place in an area where water can drip
or splash on the inverter.
B. Cool
Ambient air temperature should be between 30°F
and 105°F (0°C and 40°C). The cooler the better.
C. Ventilate

ConnectTerminals

ConnectPower Source

On/OffSwitchto On

Connect Test Load

2.Connectcables to power input terminals(see page 6 for details).

3.Connectcable to power source (see page 8 for details).

4.Check to make sure all connectionsare secure.

5.Turnthe inverteron. If the power sourceis a DC power supply,switch it on first.

6.Plug in the test load.

The invertershould supply power to the load. If the inverteris not workingproperly,refer to the troubleshootingguide on page 14 or power and protectionindicators sectionon page 12.

Allow at least one inch (three cm) of clearance

around the inverter for proper airflow. Make sure

that ventilation openings on the ends of the unit

are not obstructed.

CAUTION To avoid fire, do not cover or obstruct ventilationopenings. Do not install inverter in a zero- clearance compartment. Overheating may result.

CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery.

WARNING This unit contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment.