Troubleshooting Guide

Operation

TroubleshootingGuide

 

 

Problem/Symptom

PossibleCauses

Solution

Low output voltage

Overload

Reduce the load.

 

No output voltage

Low input voltage

Recharge battery.

 

 

Check connections

 

 

and cable.

 

No output voltage

Thermal

Allow inverter

afterprolongeduse

shutdown

to cool off.

 

 

Reduce load,

 

 

continuous

 

 

operation input

 

 

current required.

 

 

Improveventilation;

 

 

Makesure ventilation

 

 

openings in the

 

 

inverter are not

 

 

obstructed.

 

 

Reduce ambient

 

 

temperature.

 

No output voltage,

High input

Make sure

“Protect” indicator

voltage

the inverter is

lighted

 

connected to

 

 

12V battery.

 

 

Check regulation

 

 

of chargingsystem.

 

No output voltage

Short circuit

Check load for

 

 

proper operation.

 

 

 

No power to

Blown fuse

Replace fuse.

 

inverter

 

 

 

Low battery alarm

Poor DC wiring

Check

on all the time

 

connections.

 

Poor battery

Make sure battery

 

condition

is fully charged.

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . 400W Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . . 800W Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88% Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83% No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V) Output waveform (resistive load) . . . Modified sine wave Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F) Storage temperature range . . . . . . . . . . . . -40°C – 85°C (-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp, reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V.

To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for added safety.

 

 

 

 

14

Nothing Comes Close to a Cobra® 15

Page 10
Image 10
Cobra Electronics CPI 480 owner manual Troubleshooting Guide, Specifications, TroubleshootingGuide, Solution