Coleman 5076 Leak Check, Regulator/Cylinder Connection, Assembly cont, Step, Control Knob

Models: 5076

1 8
Download 8 pages 36.13 Kb
Page 5
Image 5
Step 4 (cont)
Standard 20 lb. tank

Assembly cont.

Step 4 (cont)

The support ring and each log is marked with a Letter which corre- sponds to the location where logs should be placed. Each log also has recesses that are lettered which indicate where adjoining logs are to be placed.

Start with log “A” then “B”, etc.

Step 5 (cont)

Attach regulator to tank.

 

Install tank.

 

 

 

 

 

 

Leak Check

Step 5 (cont)WARNING

Perform leak test outdoors.

Extinguish all open flames.

NEVER leak test when smoking.

Do not use the fireplace until connection has been leak tested and does not leak.

Step 5

• You must provide propane gas and propane tank. Use a standard 20 lb.

propane tank only. The L.P. cylinder must have a shut-off valve terminating

in a Type 1 L.P. gas cylinder valve outlet.

• Use this fireplace only with a propane vapor withdrawal supply system.

See Chapter 5 of the Standard for Storage and Handling of Liquefied

Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will

have this book.

• A minimum supply pressure of 11.0 W.C. is required for the purpose of

input adjustment for propane gas.

• The pressure regulator and hose assembly supplied with the fireplace

must be used.

• The installation must conform with local codes, or in the absence of local

codes, with National Fuel Gas

Code, ANSI Z223.1.

• A dented, rusted or damaged

propane tank may be hazardous

and should be checked by your

tank supplier. Never use a propane

tank with a damaged valve connec-

Cylinder Valve

Regulator/Cylinder

Connection

Make 2-3 oz. of leak check solu- tion (one part liquid dishwashing detergent and three parts water).

Apply several drops of solution where regulator connects to Cylinder.

Make sure control knob is OFF.

• Turn Cylinder Valve ON.

If bubbles appear at connection, there is a leak.

Turn Cylinder Valve OFF.

If leak is at Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s place of purchase.

If NO bubbles appear at connec- tion, the connection is secure.

• Turn Cylinder Valve OFF.

NOTE: Whenever gas connection is loosened or removed, you must perform a leak test.

tion.

• The propane tank must be

constructed and marked in

accordance with the specifications

for LP gas cylinders of the U.S.

Department of Transportation

(DOT).

• Never connect an unregulated

propane tank to the heater.

Control Knob

5

Page 5
Image 5
Coleman 5076 manual Leak Check, Regulator/Cylinder Connection, Assembly cont, Step, Control Knob