DANGER
If a fire occurs at the cylinder valve, DO NOT attempt to move the cylinder. IMMEDIATELY call the fire department and clear the area. You can safely spray water with a garden hose from a distance of at least 15 feet away from cylinder until firemen arrive.
For Your Additional Safety
Current refillable L.P. gas cylinders are fitted with an Overfill Protection Device (O.P.D.). To insure that you retain this
YOUR NEW GAS STOVE IS EQUIPPED WITH A TYPE 1 CONNECTION DEVICE WHICH HAS 3 SAFETY FEATURES (FIG. 32):
1.Proof of gas seal between the connector and the cylinder before gas flow takes place.
2.A
3.The connection has a thermal
Thermal | Nipple with | |
Sensitive | ||
Excess Flow | ||
Handwheel | ||
|
Valve
Acme Connection
Fig. 32
TYPE 1 CONNECTION
CURRENT GAS CYLINDERS ARE ALSO EQUIPPED WITH AN OVERFILL PROTECTION DEVICE (O.P.D.) WHICH GREATLY REDUCES THE CHANCE OF ACCIDENTALLY OVERFILLING THE CYLINDER.
SPECIAL NOTE CONCERNING L.P. GAS CYLINDERS:
It is important to insure that your gas cylinder is properly purged before it is filled. If you purchase a new cylinder, please inform your propane gas dealer that this is a new cylinder and needs to be properly purged before being filled.
SPECIAL NOTE CONCERNING TYPE 1 CONNECTION DEVICES:
If you notice very small flames on the burner(s), you may have accidentally activated the
1.Opening the burner valves before opening the cylinder valve.
SOLUTION: Shut off the burner valves and the L.P cylinder valve and open in the proper order:
a). Open the L.P. cylinder valve first, then b). Open burner valve and ignite the
burner according to the instructions in this manual for your stove.
IF YOU STILL HAVE A PROBLEM, THEN THERE MAY BE AIR IN THE CYLINDER DUE TO IMPROPER PURGING.
2.The L.P. cylinder was not properly purged before it was filled.
SOLUTION: See your L.P. gas supplier.