Planning Repeater Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1

Chapter 2

Planning Repeater Installation

This chapter contains installation requirements and system planning charts that will help you prepare for installing the repeater.

Installation Requirements

To help ensure a correct installation, read this section to determine the environmental, electrical, spatial, and cable requirements.

Environmental Requirements

Be sure the operating environment for the repeater is within the following ranges:

Temperature: 32° to 122° F (0° to 50° C)

Humidity: 5% to 95% (non-condensing)

Altitude: 0 to 10,000 feet (0 to 3 km)

Clearance: minimum of 2 inches (5.1 centimeters) on each side of the repeater for proper ventilation

Electrical Requirements

The electrical requirements for a repeater are as follows:

100 to 240 VAC

1.5 to 0.75 Amps (1.5 Amps @ 100 VAC to 0.75 A @ 240 VAC)

50 to 60 Hz