Basic Operation
AlphaServer Intelligent Peripheral Platform Hardware Owner's Gu ide 3–7
3.3.3 Modular Storage Shelf BA35x-Sx SubsystemThere may be up to eight StorageWorks building blocks (SBBs) on each modular storage
shelf BA35x-Sx subsystem. The StorageWorks Building Block (SBB) slots are numbered 0
through 7 from right to left with the power supply SBB in slot 7. On the IP simplex system,
the storage SBBs are in slots 0-6. On the duplex system, the available storage SBBs are in
slots 0-5.
_____________________________ Note____________________________
The SCSI address for the SSB device is defined automatically by the SSB slot
location.
______________________________________________________________
After power is supplied to the IP Platform, observe the status LEDs for the following
successful indications:
• On a power supply SBB, both green status LEDs should be on.
• On a storage SBB, the green device activity LED is either on, flashing, or off. The amber
device fault LED is off.
Additional information on the following modular storage shelf BA35x-Sx components can be
found in the BA350 Modular Storage Shelf Subsystem User’s Guide.
• Component functions
• Shelf status
• Power unit status
• Storage device status
• StorageWorks building block SSB replacement procedures
• Shelf replacement procedures
• Power supplies
• SCSI buses