Maintenance
Lamp Unit Replacement Procedure
To prevent burns, wait one hour or longer after the lamp has been switched off before performing the following procedure.
Positioning protrusions
1
2
3
4
Remove the lamp unit cover
Using a minus screwdriver, loosen the screws of the lamp unit cover, pull in the direction of the arrow, and remove the cover.
Loosen the mounting screws of the lamp unit
Using a minus screwdriver, loosen the 2 screws of
the lamp unit.
Pull out the lamp unit
Hold the handle of the lamp unit and pull it up and out.
Install a new lamp unit
Take the lamp unit and press it into the projec- |
|
tor. |
|
Check that the 2 positioning protrusions are firmly |
|
inserted into the 2 holes. | Positioning protrusions |
Tighten the 2 mounting screws of the lamp unit. |
|
Align the 2 tabs located on the lamp unit cover |
|
with the projector and attach from the side of the |
|
tabs. Tighten the mounting screws of the lamp |
|
unit cover. |
|