7.4Multi-byte commands

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgrounduSignManual backgroundUserManual backgroundManualManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

7.3.12Start Capturing use FBP format 0

Command string: D6

Response string: D6

7.4Multi-byte commands

7.4.1Initialize device

Command string: 28 10 00 00

Response string: DC 05

7.4.2Get PW120 Version

Command string: 2A 10 00 00

Response string: 01 00

7.4.3Test device

Command string: 52 12 00 00

Response string: 52 12

7.4.4Set CTS control

Command string: 22 15 01 00 01(enable)/00(disable)

Response string: 01

7.4.5Set interval between two points

Command string: 28 15 01 00 xx

Response string: 01

7.4.6Get data 0x00 0x01

Command string: 2A 15 00 00

Response string: 00 01

7.4.7Calibrate the device

Command string: 30 15 00 00

Response string: 01

7.4.8Set offset position

Command string: 31 15 04 00 xx xx xx xx(offset point)

Response string: 01

7.4.9Get data 0x01

Command string: 32 15 00 00

Response string: 01

7.4.10Offset using control

Command string: 34 15 01 00 01(enable)/00(disable)

Response string: 01

Copyright © 2006, International Technologies & Systems Corp. All rights reserved.