Continental CBI 360-P Blower System, Adjustments, Pilot Burner Adjustment, Venturi Adjustment

Models: CBI 360-N CBI 360-P

1 16
Download 16 pages 37.76 Kb
Page 10
Image 10
BLOWER SYSTEM

10

BLOWER SYSTEM

The Continental gas fireplace insert comes standard with a blower, a heat sensor, variable on/off speed control and a power cord. Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approxi- mately 30 minutes after the fireplace has been turned off. Use of the fan increases the output of heat. Air, drawn in through the lower louvre access door, is driven up the back of the firebox, and exhausted as hot air between the upper louvres.

FIGURE11

Drywall dust will penetrate into blower bearings causing irrepairable damage and must be prevented from coming into contact with the blower or its compartment.

Any damage resulting from this condition is not covered by the warranty policy.

BLOWER REPLACEMENT INSTRUCTIONS

Turn off the gas and electric power to the unit.

Remove the upper glass bracket. Loosen the lower glass bracket and remove the glass.

Remove the logs.

Remove the burner assembly.

Remove the eight screws holding the access door in place on the control assembly (located at the back of the burner support).

Remove the four screws holding the blower duct and slide it forward from beneath the burner support.

Disconnect the electrical connectors at the blower.

Remove the blower.

FIGURE12

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

1.Remove the pilot adjustment cap.

2.Adjust the pilot screw to provide properly sized flame.

3.Replace the adjustment cap.

PILOT SCREW

FIGURE12

FIGURE13

VENTURI ADJUSTMENT

Natural gas models have air shutters set at 1/16 (.063") inch open. Propane gas models have air shutters set at 3/ 16 (.188) inch open. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not ap- pear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A

QUALIFIED GAS INSTALLER!

FIGURE14

W415-0120 / E / 01.11.05

Page 10
Image 10
Continental CBI 360-P, CBI 360-N manual Blower System, Adjustments, Pilot Burner Adjustment, Venturi Adjustment