Continental CBI 360-P Operation / Maintenance, Logo Placement, Spill Switch, Venting Action Check

Models: CBI 360-N CBI 360-P

1 16
Download 16 pages 37.76 Kb
Page 8
Image 8
LOGO PLACEMENT

8

LOGO PLACEMENT

13/8"

LOGO

11/8"

Remove the backing of the logo supplied and place on the glass viewing area, as indicated.

FIGURE9

OPERATION / MAINTENANCE

SPILL SWITCH

This is a thermally activated switch, attached to the back of the unit and extending up into the dilution draft hood, which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent.

It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt gases during start up. If the flue is blocked or has no "draw", the spill switch will automatically shut off the supply of gas within about 5- 10 minutes.

TAMPERING WITH THE SWITCH CAN RESULT IN CAR- BON MONOXIDE (CO) POISONING AND POSSIBLE DEATH.

FIGURE10

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.

VENTING ACTION CHECK

A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED INSERT IS LEFT WITH THE CUSTOMER.

Test after installing the unit into a vented non-combustible fireplace in the following manner:

1.Close all doors and windows in the room; start exhaust fans in the home; turn fireplace blower off.

2.Set controls to "high" and light the unit.

3.Wait 5 minutes. Light a match and hold it to the spill tube opening.

4.Venting action is satisfactory if smoke is drawn into the spill tube. Venting action is unsatisfactory if the flame and smoke are not drawn into the tube.

5.If venting action is unsatisfactory, turn the unit off, wait 10 minutes and try again. If the smoke or flame is still not drawn into the spill tube, turn the unit off and check for vent blockage or restriction. If necessary, consult with a quali- fied air quality specialist.

After extended periods of non-operation such as follow- ing a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.