HUA
PHOTOMETRICS |
|
|
|
|
|
|
|
|
| |
Candlepower Distribution |
| Candlepower |
| Zonal Lumen Summary |
| |||||
| Test No. 1313 | Deg. |
|
| Zone | Lumens | %Lamp | %Luminaire | ||
| 0 | 1085 | 1085 | 771 | 8.1 | 15.3 | ||||
|
| |||||||||
| 5 | 1067 | 1097 | 1217 | 12.8 | 24.1 | ||||
275 | Lamp=S54 | |||||||||
15 | 1002 | 1015 | 2505 | 26.4 | 49.6 | |||||
| No. Lamps=1 | |||||||||
| 25 | 746 | 842 | 4625 | 48.7 | 91.6 | ||||
| Lumens=9500 | |||||||||
450 | 35 | 739 | 817 | 422 | 4.4 | 8.4 | ||||
Spacing Criteria | ||||||||||
| 45 | 856 | 838 | 5047 | 53.1 | 100.0 | ||||
| =.99 | =.99 | ||||||||
| 55 | 826 | 758 |
|
|
|
| |||
675 | Efficiency=53.0% |
|
|
|
| |||||
|
|
| 65 | 754 | 593 |
|
|
|
| |
900 |
|
| 75 | 660 | 427 |
|
|
|
| |
|
| 85 | 552 | 314 |
|
|
|
| ||
|
|
|
|
|
|
| ||||
|
|
| 90 | 477 | 278 |
|
|
|
| |
1125 |
|
|
|
|
|
|
|
|
|
Coefficient of Utilization
rc |
|
|
| 80% |
|
| 70% |
|
| 50% |
| 30% |
| 10% | 0% |
rw |
| 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 |
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1 | 54 | 50 | 47 | 44 | 48 | 45 | 43 | 45 | 40 | 42 | 38 | 40 | 36 | 35 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | 48 | 42 | 37 | 33 | 41 | 36 | 33 | 38 | 31 | 36 | 30 | 33 | 28 | 27 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 | 43 | 36 | 31 | 27 | 35 | 30 | 26 | 33 | 25 | 31 | 24 | 29 | 23 | 21 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | 39 | 32 | 26 | 22 | 31 | 26 | 22 | 29 | 21 | 27 | 20 | 25 | 19 | 18 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 | 36 | 28 | 23 | 19 | 27 | 22 | 18 | 25 | 18 | 24 | 17 | 22 | 16 | 15 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | 33 | 25 | 20 | 16 | 24 | 19 | 15 | 23 | 15 | 21 | 14 | 20 | 14 | 13 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 | 30 | 22 | 17 | 13 | 21 | 17 | 13 | 20 | 13 | 19 | 12 | 18 | 12 | 11 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 | 28 | 20 | 15 | 12 | 19 | 15 | 12 | 18 | 11 | 17 | 11 | 16 | 10 | 09 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 | 26 | 18 | 13 | 10 | 18 | 13 | 10 | 17 | 10 | 16 | 10 | 15 | 09 | 08 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 | 24 | 17 | 12 | 09 | 16 | 12 | 09 | 15 | 09 | 14 | 08 | 14 | 08 | 07 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.
ORDERING INFORMATION
Specifications and Dimensions subject to change without notice. | ADC041550 |
04/18/2007 11:34:04 AM |