Cooper Lighting FSR24 Test No, Lamp=3 F40T12RS, Lumens=3200, Spacing Criteria, =1.3, Candlepower

Models: FSR24

1 2
Download 2 pages 14.7 Kb
Page 2
Image 2
FSR24

FSR24

PHOTOMETRICS

Candlepower Distribution

 

 

 

 

 

 

Candlepower

 

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

Test No. 5933

 

 

 

Deg.

 

 

 

 

 

 

 

Zone

 

Lumens

%Lamp

%Luminaire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

2692

 

2692

 

0-30

 

2195

22.9

 

32.0

 

 

 

 

 

FMR24-X-340

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

5

 

2665

 

2654

 

0-40

 

3713

38.7

 

54.2

 

 

 

 

Lamp=(3) F40T12RS/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

2714

 

2627

 

0-60

 

5992

62.4

 

87.5

 

 

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

2686

 

2443

 

0-90

 

6852

71.4

 

100.0

 

 

 

 

 

Lumens=3200

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

2611

 

2143

 

90-180

 

0

0.0

 

0.0

 

 

 

 

Spacing Criteria

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

2019

 

1512

 

0-180

 

6852

71.4

 

100.0

 

 

 

 

 

 

 

=1.5

=1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

55

 

1125

 

861

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency=71.4%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

583

 

542

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2400

 

 

 

 

 

 

 

 

 

 

75

 

331

 

324

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

87

 

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

3000

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

 

 

 

70%

50%

 

 

30%

 

10%

0%

 

 

 

 

 

 

 

 

 

rw

70

50

30

10

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

85

85

85

85

83

83

83

79

79

76

76

73

73

71

 

 

 

 

 

 

 

 

1

 

79

76

74

71

75

72

70

72

68

69

66

66

64

63

 

 

 

 

 

 

 

 

2

 

73

68

64

61

67

63

60

64

59

62

57

60

56

55

 

 

 

 

 

 

 

 

3

 

68

61

56

52

60

56

52

58

51

56

50

55

49

48

 

 

 

 

 

 

 

 

4

 

63

55

50

45

54

49

45

52

44

51

44

49

43

42

 

 

 

 

 

 

 

 

5

 

58

49

44

39

49

43

39

47

39

46

38

44

38

36

 

 

 

 

 

 

 

 

6

 

53

45

39

34

44

38

34

43

34

41

34

40

33

32

 

 

 

 

 

 

 

 

7

 

49

40

34

30

40

34

30

38

30

37

30

37

29

28

 

 

 

 

 

 

 

 

8

 

45

36

30

26

36

30

26

35

26

34

26

33

26

24

 

 

 

 

 

 

 

 

9

 

42

32

27

23

32

26

23

31

23

30

22

30

22

21

 

 

 

 

 

 

 

10

39

29

24

20

29

24

20

28

20

28

20

27

20

19

rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

SAMPLE NUMBER: FSR-TG-X24-240-120-80/86-LE3-GLR

LNL= LED Night Light (50,000 hrs.) provided by Cooper

Specifications and Dimensions subject to change without notice.

ADC041611

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

03/29/2007 8:39:18 AM

Page 2
Image 2
Cooper Lighting FSR24 Test No, Lamp=3 F40T12RS, Lumens=3200, Spacing Criteria, =1.3, Efficiency=71.4%, Candlepower