PHOTOMETRICS

F W S

PHOTOMETRICS

Candlepower Distribution

 

 

 

 

Candlepower

 

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

 

Lumens

%Lamp

%Luminaire

 

 

 

 

 

Test No. 1824

 

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1291

 

1291

 

0-30

 

961

15.0

 

37.4

 

 

 

 

 

FWS-240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

5

 

1293

 

1296

 

0-40

 

1460

22.8

 

56.8

 

 

 

 

Lamp=(2) F40T12RS/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

1207

 

1213

 

0-60

 

2008

31.4

 

78.1

 

 

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

1061

 

1073

 

0-90

 

2425

37.9

 

94.3

 

 

 

 

600

Lumens=3200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

777

 

829

 

90-180

 

146

2.3

 

5.7

 

 

 

 

Spacing Criteria

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

476

 

414

 

0-180

 

2571

40.2

 

100.0

 

 

 

 

 

 

 

=1.1

=1.1

 

 

 

 

 

 

 

 

 

 

 

 

900

 

 

 

 

 

55

 

375

 

192

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency=40.2%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

299

 

77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

75

 

260

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

181

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

141

 

0

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

 

 

 

70%

50%

 

 

30%

 

10%

0%

 

 

 

 

 

 

 

 

rw

70

50

30

10

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

47

47

47

47

46

46

46

43

43

47

47

39

39

38

 

 

 

 

 

 

 

 

1

 

44

42

40

39

41

39

38

39

36

37

35

35

34

33

 

 

 

 

 

 

 

 

2

 

40

37

35

33

36

34

32

35

31

33

30

32

29

28

 

 

 

 

 

 

 

 

3

 

37

34

31

29

33

30

28

31

27

30

27

29

26

25

 

 

 

 

 

 

 

 

4

 

35

31

27

25

30

27

25

29

24

27

24

26

23

22

 

 

 

 

 

 

 

 

5

 

32

28

24

22

27

24

22

26

21

25

21

24

21

20

 

 

 

 

 

 

 

 

6

 

30

25

22

20

25

22

20

24

19

23

19

22

19

18

 

 

 

 

 

 

 

 

7

 

28

23

20

18

23

20

18

22

17

21

17

20

17

16

 

 

 

 

 

 

 

 

8

 

26

21

18

16

21

18

16

20

15

19

15

19

15

14

 

 

 

 

 

 

 

 

9

 

24

19

16

14

19

16

14

18

14

18

14

17

13

13

 

 

 

 

 

 

 

10

23

18

15

13

17

14

13

17

12

16

12

16

12

11

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041538

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/17/2007 1:35:33 PM

Page 2
Image 2
Cooper Lighting FWS-240, Photometrics, Candlepower Distribution, Zonal Lumen Summary, =1.1, Coefficient of Utilization