Gentek 9220 Wiring Two Or More Smoke Alarms, Tandem Installation, Battery Installation, Ooting

Models: 9123 9223 9120 9220

1 6
Download 6 pages 2.73 Kb
Page 5
Image 5
Smoke Alarm Wiring Diagram

 

 

Smoke Alarm Wiring Diagram

 

WHT

11

NEUT

POWER

CAUTION

 

BLK

1

HOT

 

RED/YELLOW wire to be

 

RED / YEL

10

 

TANDEM

 

VIO

7

 

CONTACTS

capped when not in use.

 

VIO / BLK

6

 

This wire is for tandem

 

 

 

 

ALARM

connection only. Do not

 

BLU

3

 

ACCESSORY

 

ORN

9

 

ALARM

connect to any other circuit.

 

 

 

 

 

YEL

4

 

CONTACTS

RATED LOAD RESISTIVE

 

BRN

5

 

ISOLATED

 

BRN

2

 

 

1.0 AMP @ 24VDC MAX

 

GRAY

8

 

THERMAL

 

GRAY

12

 

 

0.6 AMP @ 125VAC MAX

 

 

 

SMOKE

0.56 AMP @ 220VAC MAX

WIRING TWO OR MORE SMOKE ALARMS

 

PLUG

 

ALAR

 

Tandem Installation

 

NOTICE:

All smoke alarms in a tandem installation must be

controlled by the same fuse or circuit breaker. Otherwise tandem units

will not operate. Tandem will operate in the event of AC power failure if

battery is connected to the smoke alarm.

LIMITATIONS: A maximum of 12 smoke alarms (9120/9123 or

9220/9223) may be connected together. Do not exceed 125 feet

between each smoke alarm. Do not exceed 1125 feet between first

and last smoke alarm.

 

 

NOTICE:

A maximum of six (6) smoke alarms of either model

9120/9123 or 9220/9223 with the relay options (F, TF, HF) may be

tandem interconnected.

 

 

Wire used for interconnection shall be in accordance with article

760 of the latest edition of National Electrical Code (NFPA 70) and

must not exceed a resistance of 10 ohms.

VAC

BOX

 

QUICK DISCONNECT

LIMITATIONS

 

ELECTRICAL

 

TYPE PLUG

Maximum of 12

 

 

ALARM

smoke alarms may be

 

 

 

 

SMOKE

 

 

 

 

 

 

connected together.

 

 

 

 

 

Do not exceed 125

 

ELECTRICAL

 

SMOKE

feet between each

 

BOX

 

smoke alarm. Do not

 

 

 

 

ALARM

exceed 1125 feet

 

 

 

 

 

between the first and

 

TANDEM WIRE

TO ADDITIONAL

last smoke alarm.

 

RED / YEL

 

 

NEUTRAL / WHITE

SMOKE ALARMS

 

 

 

 

(MAX 12 ALARMS

 

 

HOT / BLACK

PER SYSTEM)

 

1. Run a minimum of 16 gauge, 3-conductor cable, plus ground (4

wires) to the first alarm junction box from a power supply and between

all smoke alarms that are to be connected together. Use ANSI/UL

Listed Class 1 wire. Power limited cable for multiple tandem

connections are available at many commercial electrical retail stores.

2. Make wire connections to the supplied plug-in connector as follows:

black to black, white to white, 3rd conductor to the red/yellow wire.

The red/yellow wire should be stripped to make the connection.

Connect ground wire between metal outlet boxes.

NOTES ON TANDEM INTERCONNECTING MODELS

￿ DO NOT connect Gentex smoke alarms to other manufacturers' smoke alarms.

￿ No more than 12 Gentex models 9120T, H/9123T, H or 9220T, H/ 9223T, H may be connected in tandem.

￿ No more than 6 Gentex models 9120F, TF, HF/9123F, TF, HF or 9220F, TF, HF/9223F, TF, HF may be connected in tandem.

￿ All units connected in tandem MUST get their power from the same circuit, that is, all smoke alarms in tandem must be controlled by the same fuse or circuit breaker.

￿ After installation to verify proper working conditions all horns must sound in this system.

NOTICE: If all interconnected alarms do not emit alarm signal during commissioning test, refer to “WIRING TWO OR MORE SMOKE ALARMS” section to insure alarm wiring is in accordance with tandem wiring diagam.

CAUTION: Failure to observe any of the conditions set forth may cause system malfunction and damage to the smoke alarm.

BATTERY INSTALLATION

1. Remove smoke alarm from mounting plate by turning counter- clockwise.

2. Remove AC power connector and unsnap power leads from top of the old battery. Snap new battery onto snaps and reinsert battery through hole in back of smoke alarm. WARNING: Units with battery back-up will not provide power or transmit an alarm to AC only units in the event of an AC power failure. All battery back-up units in tandem with good batteries will operate normally during an AC power failure for a minimum of 24 hours.

3. Use only Duracell MN 1604 battery with the 9000 Series smoke alarms. Available at many retail stores.

MOUNTING: PLATE & SMOKE ALARM

1. Lace the connector through the provided mounting plate and secure the plate to the junction box.

2. Plug the wire connector into the smoke alarm base.

3.Place smoke alarm up to mounting plate, rotating it clockwise until smoke alarm firmly snap locks into place. Keep smoke alarm parallel to mounting plate so upper and lower tabs on plate seat correctly into smoke alarm.

STARTFINISH

 

 

WORK CONNECTOR WIRES BACK

ROTATE ALARM TO UPRIGHT

 

 

THROUGH HOLE IN ADAPTER PLATE

POSITION

CHE

CKOUT & TROUBLESH

OOTING

1.

Turn test knob to NORMAL position and install battery and then

 

supply house power to smoke alarm. The red indicator light should

 

flash every 15-30 seconds, showing smoke alarm is Operating

2.

properly.

 

If red light is not flashing or the green LED is not on:

a. Check that the battery is installed.

 

b. Check the connector plug and wire connections. NOTE: Be sure you

 

turn off power before checking wire connections.

c. If power supply and wiring check out, but red light does not flash or

 

green LED is still off, return the smoke alarm to manufacturer. See

 

TO RETURN A SMOKE ALARM.

 

d. When powering up smoke alarms in a tandem installation and all

 

smoke alarms sound immediately, inspect all smoke alarms for

 

those with an illuminated indicator light. These will be the trouble

 

units.

 

3. Testing with Test Knob:

 

a. Rotate test knob counter-clockwise to TEST 1 position and wait up to 20 seconds for smoke alarm to sound. If smoke alarm does not sound after 20 seconds, return smoke alarm for service.

b. After successfully testing smoke alarm, return test knob to NORMAL (non-test) position and wait 20 seconds for alarm to stop sounding.

c. To test smoke alarm for high sensitivity, turn test knob clockwise to TEST 2 position. Alarm should remain silent.

d. Make sure to return test knob back to its normal position.

e. If your smoke alarm sounds during this test it means the smoke alarm's sensitivity has become too high and may cause false alarms.