COOPER LIGHTING - SURE-LITES®
DESCRIPTION
The real workhorse in emergency lighting systems...these durable, reliable units are unparalleled in performance and provide freedom from maintenance. The HR Series units provide a
Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
Electronic
-Dual Voltage Input 120/277 VAC, 60 Hz
-
-
-
-
-Brownout Circuit
-Overload/Short Circuit Protection
-Test Switch/Power Indicator Light
-Isolation Transformer
Housing Construction
-
-
-Knockout, Conduit or Cord Set
-Universal
Housing Construction Cont. | Warranty | |
- Keyhole Mounting Slots | - Unit: | |
- White Finish | - Battery: | |
Battery | Head/Lamp Data | |
- Sealed Lead Calcium, | - Two Heads Standard | |
Recombination | - Top Mounted | |
- | - | |
- Full Recharge Time, | - Fully Adjustable | |
24 hrs. (max.) | - Remote Capability | |
- Polarized Battery Terminals | - Metal Heads with Die Cast | |
Code Compliance | Metal Swivel | |
- Halogen Lamp Standard | ||
- UL 924 Listed | - Matches Housing Finish | |
- City of Chicago Approval |
|
|
No. 3238 |
|
|
- Life Safety NFPA 101 |
|
|
- CSA Certified (HR12117 Only) |
|
|
- NEC/OSHA |
|
|
- Most State and Local Codes |
|
|
|
| |
|
|
HR87C
HR117C
HR12117C
H I G H C A PA C I T Y S E A L E D L E A D C A L C I U M B AT T E RY
| [362mm] |
| 1/4"14 |
| [203mm] |
| 8" |
4 1/4" | 12 1/2" |
[108mm] | [318mm] |
5 3/4" | 14 1/2" |
[146mm] | [368mm] |
18"
[457mm]
113/4"
[299mm]
| 8 1/4" |
|
| 17 1/4" |
|
| ||||
| [210mm] |
|
|
|
|
|
| |||
|
| [438mm] | ||||||||
| 9" |
|
|
| 19 1/4" |
|
| |||
[229mm] | ||||||||||
| [489mm] |
|
HR180C HR12170C
|
|
|
| Figure 1 High Capacity |
| Figure 2 Ultra High Capacity | ||||||
ORDERING INFORMATION |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| S A M P L E N U M B E R : H R 8 7 C T D M |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HR |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Model Number |
| Options (add as suffix) |
| Accessories (order separately) | |||||||
| HR87C |
| Alternate Lamps: Consult Cooper Lighting |
| VK1=Voltmeter | |||||||
| HR117C |
| Representative |
| 3BRWH=Mounting Brackets | |||||||
| HR12117C |
| A=Ammeter |
| 2MSWH=Mounting Shelf (High Capacity Units) | |||||||
| HR180C |
| V=Voltmeter |
| 3MSWH=Mounting Shelf | |||||||
| HR12170C |
| TDM=Time Delay Monitor |
| CSK120=Cord Set (120 VAC) | |||||||
| HR12210C |
| Other Options: Consult Cooper Lighting |
| CSK277=Cord Set (277 VAC) | |||||||
| ||||||||||||
| HR12360C |
| Representative |
| VS2=Polycarbonate Vandal Shield | |||||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| WG7=Wire Guard (High Capacity units) | ||
|
|
|
|
|
|
|
|
|
| WG3=Wire Guard (Ultra High Capacity units) |
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
HR12210C
HR12360C
U LT R A H I G H C A PA C I T Y S E A L E D L E A D C A L C I U M B AT T E RY
Chicago Code
Emergency Lighting
E N E R G Y D ATA |
| |
HR87C | HR12170C | |
Input Current (Max.): | ||
Input Current (Max.): | ||
120V= .50A | ||
120V= 1.08A | ||
277V= .21A | ||
277V= .45A | ||
HR117C | ||
HR12210C | ||
Input Current (Max.): | ||
Input Current (Max.): | ||
120V= .53A | ||
120V= 1.02A | ||
277V= .22A | ||
277V= .47A | ||
HR12117C | ||
HR12360C | ||
Input Current (Max.): | ||
Input Current (Max.): | ||
120V= .26A | ||
120V= 1.17A | ||
277V= .13A | ||
277V= .54A | ||
HR180C | ||
| ||
Input Current (Max.): |
| |
120V= .98A |
| |
277V= .43A |
|
ADX041293 03/21/2007 11:33:08 AM