ELECTRICAL RATINGS | CHICAGO HR SERIES |
| Rated Wattage to 87 1/2% of Rated D.C. Voltage |
| ||||
Model | Type | DC Voltage 1 1/2 Hours | Lamp Watts | Remote Watts | ||
HR87C | SLC | 6 |
| 87 | 24 | 63 |
HR117C | SLC | 6 |
| 117 | 24 | 93 |
HR12117C | SLC | 12 |
| 117 | 24 | 93 |
HR180C | SLC | 6 |
| 180 | 24 | 156 |
HR12170C | SLC | 12 |
| 170 | 24 | 146 |
HR12210C | SLC | 12 |
| 210 | 24 | 186 |
HR12360C | SLC | 12 |
| 360 | 24 | 336 |
*Batteries may be shipped separately. | SLC=Sealed Lead Calcium |
|
PHOTOMETRICS
Lamp Information
Type | Wattage | Number | Figure |
Halogen | 12 | 1 | |
Halogen | 12 | 1 | |
Halogen | 12 | 1 | |
Halogen | 12 | 2 | |
Halogen | 12 | 2 | |
Halogen | 12 | 2 | |
Halogen | 12 | 2 |
H o r i z o n t a l D i s t r i b u t i o n
15 |
|
|
|
|
|
|
FEET |
|
|
|
|
|
|
LEFT |
| 1FC | 0.5 | 0.3 | 0.2 | 0.1 LAMP |
0 |
| |||||
|
|
|
|
| AXIS | |
FEET |
|
|
|
|
| |
|
|
|
|
|
| |
RIGHT |
|
|
|
|
|
|
150 | 20 | 30 | 40 |
| 50 | 60 |
FEET FROM LAMP (Measured on axis)
Lamp No.
Initial Lumens – 302
Ve r t i c a l D i s t r i b u t i o n
15 |
|
|
|
|
|
|
FEET |
|
|
|
|
|
|
LEFT |
| 1FC | 0.5 | 0.3 | 0.2 | 0.1 LAMP |
0 |
| |||||
|
|
|
|
| AXIS | |
FEET |
|
|
|
|
| |
|
|
|
|
|
| |
RIGHT |
|
|
|
|
|
|
150 | 20 | 30 | 40 | 50 |
| 60 |
FEET FROM LAMP (Measured on axis)
Lamp No.
TECHNICAL DATA
Heads
All metal formed aluminum lampheads. The die cast metal three dimensional swivel assembly permits approximate aiming adjustment from 80° vertical and 358° rotation. The placement is secured with a lockable pivot mounted on a rotating base ring.
Lamps
Designed specifically for emergency lighting applications, the PAR 36 sealed beam type design insures optimum glare- free light distribution along with horizontal and vertical adjustment by rotating the lens within the housing. Tungsten halogen lamps maximize light output with lower wattage.
Housing
The rugged
Line - Latched
a
Solid - State Charger
Supplied with a 120/277 VAC, voltage regulated
Overload and Shor t
Circuit Protectio n
The
Brownout Circuit
The brownout circuit in Sure- Lites’ units monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction
of AC power occurs. This
dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred.
Solid - State Transfer
The unit incorporates a solid- state switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of the AC power, the emergency lamps will switch off and the charger will automatically recharge the battery.
Low - Voltage Disconnect
When the battery’s terminal voltage falls below 80% of the rated voltage, the
Test Switch/Power Indicator Ligh t
Conveniently located Test Switch allows for manual verification of proper operation of the transfer circuit and emergency lamps. The Power Indicator Light provides visual assurance that the AC power is on.
Sealed Lead Calcium Battery
The fully sealed,
Warranty
All
Specifications and Dimensions subject to change without notice. | ADX041293 |
03/21/2007 11:33:08 AM |