INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING LUMINAIRE.

RETAIN FOR FUTURE REFERENCE.

Poles

Sheet 1 of 3

2/15/08 IMI-484

!WARNING

Make certain power is OFF before starting installation or attempting any maintenance.

FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH.

General: Upon receipt of pole thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the label on the pole to be sure the correct merchandise has been received.

Safety: This pole must be grounded in accordance with the National Electrical Safety Code and applicable local codes and

ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. This pole is not suitable for Hazardous or Classified Locations. This product must be installed in accordance with the applicable instal- lation code by a person familiar with the construction and operation of the product and the hazards involved. Consult a qualified electri- cian to ensure correct branch circuit conductor.

ANCHOR BOLTS

1.Only bolt and nut kits supplied by Cooper Lighting should be used.

2.Existing anchor bolts or bolt adapters supplied by other than Cooper Lighting should not be used. If they are, Cooper Lighting assumes no responsibility in case of bolt or adapter failure.

3.Anchor bolt and nuts from other sources should be used only on the advice of a Structural Engineer. Fasteners not suitable for this application can result in bolt and/or thread failure and consequent collapse of the pole.

CAUTION: Use of nuts from other manufacturers with Cooper Lighting bolts may result in thread failure caused by improper thread fit.

4.In addition to electrical conduit and other equipment necessary to the installation, the foundation bolts should be cast into concrete, in conformance with the template drawing supplied with the anchor bolts for each particular pole.

CAUTION:

A.Check all templates for dimensional accuracy before using them to locate bolt position in the foundation.

B.Be certain that anchor bolts are properly located to provide the desired directional orientation of the pole.

C.Be certain that the anchor bolts are plumbed vertically, and they extend above the finished surface of the foundation to the extent called for on the bolt template drawing.

FOUNDATIONS

Since local soil and frost conditions vary widely a Civil Engineer familiar with these conditions should be consulted regarding dimensions and depths of foundations.

POLE ERECTION AND FIXTURE INSTALLATION

1.All Cooper Lighting steel poles are to be installed using two nuts on each anchor bolt. The first nuts are to be run down on the thread to the top of the foundation and be checked using a hand level to ensure that the top surfaces of all these nuts are the same height. The pole should then be installed with its base plate holes over the bolts and the second nut screwed down to a moderate degree of tightness. The pole then should be checked and adjustments made to ensure that the pole is plumb. When this is satisfactory, tighten the top nuts to the proper torque values as shown using torque wrench.

Bolt Diameter in Inches

3/4

1

1 3/4

1 1/2

 

 

 

 

 

Recommended Ft. lbs. of torque when nuts are not lubricated

105

250

500

870

 

 

 

 

 

Fecommended Ft. lbs. of torque when nuts are lubricated

78

190

380

650

 

 

 

 

 

2.When the installation is complete and confimred to be correct, the void that appears between the base plate and concrete foundation is to be filled using a non-shrinking mortar grout. Then shape and finish to a neat appearance.

3.With the exception of the instructions presented on this page, the procedures for fixture installation and pole erection are the responsibility of the installation contractor

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-484 ACF080468

Page 1
Image 1
Cooper Lighting IMI-484 dimensions Poles Sheet 1, Anchor Bolts, Foundations, Pole Erection and Fixture Installation

IMI-484 specifications

Cooper Lighting's IMI-484 is a state-of-the-art industrial lighting solution engineered for high-performance applications. Designed with versatility and efficiency in mind, the IMI-484 is suitable for various environments including warehouses, factories, and distribution centers, where optimal lighting is crucial for safety and productivity.

One of the standout features of the IMI-484 is its robust construction. Built with durable materials, it can withstand the rigors of industrial use. The fixture is designed to resist dust, moisture, and impact, making it a reliable choice for demanding settings. This durability ensures that companies can depend on the IMI-484 for years without the need for frequent replacements or significant maintenance.

The IMI-484 utilizes advanced LED technology, providing high energy efficiency while delivering excellent light output. With a luminous efficacy that surpasses traditional lighting solutions, this fixture significantly reduces energy consumption, which translates into lower operational costs for businesses. Furthermore, it is available in various wattages and color temperatures, allowing users to customize their lighting experience to meet specific operational requirements.

Another key characteristic of the IMI-484 is its innovative optics design. With a well-distributed light pattern, it minimizes shadows and provides consistent illumination across large areas. This feature is particularly important in environments where precise visibility is necessary for tasks that require focus and safety.

The IMI-484 also boasts intelligent control systems, offering options for integration with smart building technologies. By utilizing occupancy sensors and daylight harvesting capabilities, users can further optimize energy savings by ensuring that lights are only on when needed.

In terms of installation, the IMI-484 is designed for flexibility. It can be easily mounted in various ways, whether suspended, surface-mounted, or wall-mounted. This adaptability makes it suitable for a wide range of applications and simplifies the installation process for contractors.

In summary, Cooper Lighting's IMI-484 stands out as a highly efficient, durable, and adaptable industrial lighting solution. With its advanced LED technology, robust construction, innovative optics, and smart controls, the IMI-484 is engineered to enhance productivity and safety in any industrial environment while providing significant cost savings over time.