Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.
Installation Instructions
Sheet 1 of 3
Roundel, XL
IN/OUTDOOR
P1R (Pendant,
Visor and
3.
Securing and Wiring the Fixture Head to Pendant
Electrical cover plate
Wire connector
Aiming screw spacer
(x2)
| |
| Hex end bolt |
End cap | (x2) |
1.While firmly supporting fixture head, use
2.Slide one aiming screw spacer between fixture head and yoke arm on each side and secure fixture heads angle using
3.Remove electrical cover plate from pendant tube.
4.Insert fixture head wire into wire connection at base of pendant tube and run up to electrical cover plate.
5.Attach appropriate wires ensuring all connections are properly matched and replace electrical cover plate.
4.
Electrical cover plate gasket
Wire connectors (x2)
End cap (x2)
Aiming and Sealing Fixture
Captive door screws (x10)
40
Side View
1.To aim fixture, unscrew end caps from fixture. Loosen both
2.Secure door using proper torque specifications and sequence as described in supplementary sheet.
3.Thoroughly check seal on all gaskets and wire connectors to ensure seals are smooth and compressed.
ADY080866 REV A(ECN080377)