Lincoln Electric SVM133-B service manual Adjust wire feed speed at the SG Control Module

Models: SVM133-B

1 197
Download 197 pages 45.78 Kb
Page 35
Image 35

C-9

C-9

ACCESSORIES

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

CONNECTION OF THE K488 SG CONTROL MODULE AND K487 MAGNUM SPOOL GUN TO THE COMMANDER 400 (SEE FIGURE C.7.)

1.Shut the welder off.

2.Connect the electrode cable from the SG Control Module to the “+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.

NOTE: Welding cable must be sized for current and duty cycle of application.

NOTE: Figure C.7 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the Commander 400 output terminals.

3.Connect the K691-10 input cable as shown in Figure C.7.

4.Set the slide switch on the SG Control Module to the “Lincoln” position.

CAUTION

Be sure this switch is set to the “Lincoln” (contact clo- sure) position before attempting to operate the SG Control Module. Incorrect switch position could result in damage to the SG Control Module and/or the Commander 400.

5.Place the IDLER switch on the Commander 400 in the “HIGH” position.

CAUTION

Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor set- ting is preset at the factory — do not adjust above RPM specifications listed in this manual.

6.Set the LOCAL/REMOTE switch to “REMOTE” if a K857 remote control is used. Set the switch to “LOCAL” if no remote control is used.

7.Set the VOLTMETER switch to “+” or “-” depend- ing on the polarity chosen.

8.Set the RANGE switch to “WIRE WELDING CV.”

9.Set the WELDING TERMINALS switch to “WELD-

ING TERMINALS REMOTELY CONTROLLED.”

10.Adjust wire feed speed at the SG Control Module.

NOTE: For remote control, a K857 remote control is required. Connect it to the 6 pin amphenol.

Return to Section TOC

Return to Master TOC

FIGURE C.7

COMMANDER 400/K691/K488/K487 SPOOL GUN CONNECTION DIAGRAM

115V RECEPTACLE

K488 SG

CONTROL MODULE

14 PIN WIRE FEEDER

 

K691-10

RE C EP TACLE

6 PIN REMOTE

 

 

RECEPTACLE

 

INPUT CABLE

TO WORK

ELECTRODE

 

 

ELECTRODE CABLE

K487-25

SPOOL GUN

Return to Section TOC

Return to Master TOC

TO WORK

TO CONTROL MODULE

COMMANDER 400

Page 35