Lincoln Electric SVM133-B service manual Normal Open Circuit Voltage Waveform Wire CV TAP

Models: SVM133-B

1 197
Download 197 pages 45.78 Kb
Page 130
Image 130

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-76

F-76

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (WIRE CV TAP)

MAX CONTROL POT – HIGH IDLE – NO LOAD

0 volts

This is the typical DC open circuit output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at “WIRE” welding output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

COMMANDER 400

Page 130
Image 130
Lincoln Electric SVM133-B Normal Open Circuit Voltage Waveform Wire CV TAP, MAX Control POT High Idle no Load