TROUBLESHOOTING & REPAIR | ||||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | |
|
|
| detailed in the beginning of this manual. | |
|
|
|
| |
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
|
|
| |
|
| WELDING PROBLEMS |
| |
The welding arc is “cold.” The |
|
|
| 11. Check for poor connection at |
engine runs normally. The auxiliary |
|
|
| J21 pins 1 & 4 at the CV daugh- |
power is normal. (Continued) |
|
|
| ter board. This is CVSCR gate |
|
|
|
| drive output. Will not affect |
|
|
|
| welding in the general fab or |
|
|
|
| pipe taps. |
|
|
|
| 12. Check for poor connection |
|
|
|
| along lead #208 at the negative |
|
|
|
| CV output stud and at J21 pin 6 |
|
|
|
| molex plug at the CV daughter |
|
|
|
| board. This is CV voltage feed- |
|
|
|
| back input. Will not affect weld- |
|
|
|
| ing in the general fab or pipe |
|
|
|
| taps. |
|
|
|
| 13. Check the weld & CV chokes (if |
|
|
|
| so equipped) for turn to turn |
|
|
|
| shorts. |
|
|
|
| 14. Check all waveforms as illus- |
|
|
|
| trated in the Oscilloscope |
|
|
|
| Waveforms Section. |
|
|
|
| 15. Perform the Control Board |
|
|
|
| Power Supply Test. |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-