TROUBLESHOOTING & REPAIR

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 400AMPS AT 40 VOLTS

0 volts

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.

The machine was loaded with a resistance grid bank to 400 amps at 40 volts.

Note: Scope probes connected at “STICK” welding output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 