OPERATION
CONTROLS AND SETTINGS
The welder/generator controls are located on the case front panel. Refer to Figure B.1 and the explanations that follow.
FIGURE B.1 – CASE FRONT PANEL CONTROLS
1 | 2 | 3 | 4 | 5 |
| 6 | 7 | 8 | |
9 |
|
|
|
|
|
|
|
| 9 |
|
|
|
|
|
|
|
|
| |
|
|
| OIL |
|
|
|
|
|
|
FUEL |
| TEMP | PRESS |
| AMPS | 0 0 0 | H0O U0R S | 0 | 11 |
1 0
1 2
2 3
1 3
1 7
2 2
2 1
2 4
-
2 0
+-
1 8 | 1 5 | 1 6 |
1 4
1 9
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
ENGINE CONTROLS
(Figure B.1, Items 1 through 8)
See Figure B.1 for the location of the following fea- tures:
1.RUN-STOP SWITCH: When placed in the “RUN” position, this switch energizes the fuel solenoid and other electric accessories. When placed in the “STOP” position, the flow of fuel to the injection pump is stopped to shut down the engine.
NOTE: If the switch is left in the “RUN” position and the engine is not running, the battery will be drained by the fuel solenoid.
2.START PUSHBUTTON: Energizes the starter motor to crank the engine. With the engine RUN- STOP switch in the “RUN” position, push and hold the START button for a minimum of 2 seconds to crank the engine; release as the engine starts. Do not press while engine is running since this can cause damage to the ring gear and/or starter motor.