Haier FCD-JTSA70-III, FCD-JTSA50-III Setting Environment, Connection and use of safety valve

Models: FCD-JTSA50-III FCD-JTSA60-III FCD-JTSA70-III

1 6
Download 6 pages 8.57 Kb
Page 6
Image 6

Setting Environment

Do not set it at place where is too cold and

 

may freeze.

Do not set at outdoor places.

Do not use as floorstanding appliance.

Please mount it to firm and reliable wall.

 

In case connecting water heater with water drain hose,

Do not install to places without sewer.

connect the drain hose to the inlet of the sewer to avoid

polluting by splashing.

 

The original pipeline of the water heater is an organic part of "PTO 0". Do not remove it by yourself. Otherwise we will not take responsibility for the injure and loss caused by the safety trouble occurred therefrom.

Description of the Symbols

Never do that

Be sure to act as per instructions

58

Installation

Be sure to have it installed by installation staff of the after service

department, or the appointed staff. It adopts wall-mounting installation.

Make four holes with diameter of 12mm and depth 65mm with churn drill

on the wall as per the installation dimension drawing. Insert the bolts into

the holes. Then lift the water heater, set the wall-mounting rack on the bolt.

Set the gasket and fasten the nut. Install the accessories including safety

valve etc. as indicated in Figure 2. Remember to seal with rubber tape to

avoid water leakage.

To facilitate the installation and dismantling, it is suggested to add G 1/2'

flexible nut at the suitable position of the water inlet and outlet pipe

separately. Confirm the position needing water supply. Connect the water

inlet/outlet pipe and tap water pipe to the position respectively.

The hot water pipe shall not be too long to reduce the heat losses.

Please reserve some space in installation for the future maintenance.

(Figure 2) for reference in installation only

 

 

Hot

 

 

 

water

Safety valve

 

 

outlet

 

 

 

Cold water inlet

 

Hot water

Cold water

Shower nozzle

 

outlet valve

 

outlet valve

Mixing valve

 

 

Connection and use of safety valve:

The safety valve should be connected to the cold water inlet pipe. Please check carefully if the direction is correct after installation. The correct direction of installation is that the arrowhead on the safety valve should point to the water heater.

Please connect the drain hose to the safety valve. Connect one end of the hose to the safety valve vent and the other end to the sewage drain. The hose can be cut short or extended as necessary. The hose shall be installed as inclined downward.

6

Page 6
Image 6
Haier FCD-JTSA70-III, FCD-JTSA50-III, FCD-JTSA60-III user manual Setting Environment, Connection and use of safety valve

FCD-JTSA50-III, FCD-JTSA60-III, FCD-JTSA70-III specifications

Haier, a global leader in home appliances, has introduced a series of innovative washing machines that cater to the needs of modern consumers. The FCD-JTSA70-III, FCD-JTSA60-III, and FCD-JTSA50-III models are designed with advanced features and technologies, ensuring optimal performance, energy efficiency, and ease of use.

The FCD-JTSA70-III is the flagship model, boasting a generous 7 kg washing capacity, making it ideal for larger families or individuals who tend to have frequent laundry needs. One of its standout features is the Direct Drive Motor Technology. This technology reduces noise, enhances energy efficiency, and increases durability by eliminating the need for belts and pulleys. The machine also incorporates Smart Sensing Technology, which automatically detects the load size and adjusts water consumption accordingly, ensuring that users do not waste resources.

On the other hand, the FCD-JTSA60-III offers a 6 kg capacity and is perfect for mid-sized households. This model shares many of the advanced features found in the FCD-JTSA70-III, including the Direct Drive Motor and Smart Sensing Technology. Additionally, it includes a user-friendly LED display panel that makes it easy for users to select from various washing programs. A notable addition to this model is its Anti-Bacterial Drum, which ensures that the inner drum remains hygienic, keeping clothes cleaner and safer for family use.

Lastly, the FCD-JTSA50-III is an efficient 5 kg capacity washing machine, tailored for smaller households or individuals. While it may be smaller, it doesn't compromise on functionality. Like its larger counterparts, it employs the Direct Drive Motor, ensuring quiet performance and low energy consumption. This model also includes a compact design, allowing it to fit comfortably in limited spaces without sacrificing functionality.

All three models showcase Haier's commitment to sustainability through energy-efficient designs and water-saving technologies. Each machine is equipped with multiple washing modes, catering to various fabric types and soiling levels, ensuring optimal care for garments.

In conclusion, Haier's FCD-JTSA70-III, FCD-JTSA60-III, and FCD-JTSA50-III washing machines combine cutting-edge technology with practical features. From energy efficiency to user-friendly designs, these models address the diverse needs of consumers while promising reliability and outstanding cleaning performance.