8
Cleaning and MaintenanceBe sure to switch off the power supply before cleaning. Use humid cloth with neutral detergent to wipe the shell gently. Do not use petrol and other solvent. Finally wipe it with dry cloth and keep the shell dry. To guarantee the high-efficiency operating of the water heater, please clean the electric heating pipe and inner tank every three years. Do not damage the protection coating outside the electric heating element and inside the inner tank. The Magnesium anode rod shall also be replaced periodically according to the local water quality. Please contact the local maintenance department for maintenance service. UsageAfter installation, as the tank is empty in the first usage, be sure to open the faucet water inlet valve and mixing valve. When the tank is filled with water, and the shower nozzle or other water outlet keeps water outputting, please close the mixing valve, check if there's water leakage at each joint, and plug the power plug. Turn the knob as per the needed water temperature. The mark of knob increases from water inlet temperature to 75 . You can set heating temperature steplessly. The heating indicator will light on under heating mode. Generally the knob should be set to the highest scale. The water heater can regulate the temperature automatically. The power will be switched off automatically when the set temperature is reached, and will be switched on automatically when the temperature drops to certain level. As it continues heating, you can use hot water as well. When the tap water inlet pressure arrives or exceeds 0.75 Mpa, the drain hose of safety valve will discharge large amount of water. It is due to extra high water pressure. Please contact the local after service for disposal.
Rated voltage: 230V~,50Hz Dimension: (See to Figure 1)
Power: 1650W Weight: (See to Figure 1)
Rated pressure: 0.75MPa Volume: (See to Figure 1)
Waterproof grade: IPX 4( ) Tap water pressure: no less than 0.05MPa
ParametersDimension

Front view Cutaway view Bottom view

Remarks: the permitted error limit of above parameters is 10%Figure 1Electric Circuit DiagramL:Brown wireN:Blue wireMT: High temperature limiterBT: ThermostatHL:Heating indicatorEH:Heating elementE:Yellow/green wire
L
NE
BT
HL
EH
E
MT
3A Hot water outletB Cold water inletC Heating elementD Enamel tankE Wall-mounting bracket
f1
a1
b1
d1
e1
C1
AB
C
D
E
Model Volume Netweight

a1 b1 c1 d1 e1

390mm
390mm
100mm
100mm
683mm
765mm
197mm
197mm
390mm
390mm
19kg
21kg
50L
60L

f1

220mm
320mm
390mm
100mm865mm 197mm
390mm
23kg
70L 420mm