TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)

HIGH IDLE – NO LOAD – OUTPUT CURRENT CONTROL AT MAXIMUM

15.8 ms

0 volts

This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 5 milliseconds in time.

Note: Scope probes connected at machine 115VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

COMMANDER 400