| TROUBLESHOOTING & REPAIR | |||
| COMMANDER 400 WITH | |||
|
|
| ||
ERROR CODES DURING | DEFINITION / SYMPTOM | CORRECTIVE ACTION | ||
INITIALIZATION SEQUENCE | ||||
|
| |||
|
|
|
| |
LCH |
| The output current is too high | The machine may be “over | |
|
| (greater than 750 amps for more | loaded.” Remove any external | |
|
| than 1 second). | loads. If the problem persists | |
|
|
| with no external load, check the | |
|
|
| shunt leads and associated con- | |
|
|
| nections to the control board. | |
|
|
| See the Wiring Diagram. Perform | |
|
|
| the SCR/Diode Rectifier Bridge | |
|
|
| Test. | |
|
|
| If the above procedures | |
|
|
| do not reveal the problem, the | |
|
|
| control board may be faulty. | |
|
|
|
| |
Err |
| XIRQ error (illegal external | If a High Frequency unit is being | |
|
| interrupt request). | used, make sure it is connected | |
|
|
| properly. There may be high | |
|
|
| frequency intrusion from another | |
|
|
| source in the immediate area. | |
|
|
| Remove all possible forms of RF | |
|
|
| intrusion. | |
|
|
| If the problem persists, the | |
|
|
| control board may be faulty. | |
|
|
|
|