F-19

 

 

F-19

 

TROUBLESHOOTING & REPAIR

 

COMMANDER 400 WITH G2713-1 CONTROL BOARD

 

 

 

ERROR CODES DURING

DEFINITION / SYMPTOM

CORRECTIVE ACTION

INITIALIZATION SEQUENCE

 

 

 

 

 

 

LCH

 

The output current is too high

The machine may be “over

 

 

(greater than 750 amps for more

loaded.” Remove any external

 

 

than 1 second).

loads. If the problem persists

 

 

 

with no external load, check the

 

 

 

shunt leads and associated con-

 

 

 

nections to the control board.

 

 

 

See the Wiring Diagram. Perform

 

 

 

the SCR/Diode Rectifier Bridge

 

 

 

Test.

 

 

 

If the above procedures

 

 

 

do not reveal the problem, the

 

 

 

control board may be faulty.

 

 

 

 

Err

 

XIRQ error (illegal external

If a High Frequency unit is being

 

 

interrupt request).

used, make sure it is connected

 

 

 

properly. There may be high

 

 

 

frequency intrusion from another

 

 

 

source in the immediate area.

 

 

 

Remove all possible forms of RF

 

 

 

intrusion.

 

 

 

If the problem persists, the

 

 

 

control board may be faulty.

 

 

 

 