TROUBLESHOOTING & REPAIR
TOC | TOC | ABNORMAL SOLENOID PULL & HOLD COIL WAVEFORMS | |||
Return to Section | Return to Master |
|
|
|
|
TOC | TOC |
|
|
|
|
Returnto Section | Returnto Master | SCOPE SETTINGS | SCOPE SETTINGS | ||
|
| 1V | 20 ms | 200 MV | 5 ms |
|
| Volts/Div | 1V/Div. | Volts/Div | 200 MV/Div. |
|
| Horizontal Sweep ... | 20 ms/Div. | Horizontal Sweep | 5 ms/Div. |
|
| Coupling | DC | Coupling | DC |
|
| Trigger | Internal | Trigger | Internal |
TOC | TOC | The scope pictures above are exam- | |
Section | Master | ||
ples of a short at the output of both | |||
|
| ||
|
| the pull and the hold coil circuits on | |
to | to | the control PC board. The overcur- | |
rent circuits in the pull and hold coil | |||
Return | Return | ||
circuits will shut down the circuit when | |||
|
| ||
|
| an overcurrent is sensed, preventing | |
|
| damage to the circuit. The waveform | |
|
| on the left will cause the solenoid to | |
|
| not pull in. The waveform on the right | |
|
| will cause the solenoid to pull in, then | |
|
| drop out. Check for shorted solenoid | |
|
| coils and grounded leads. | |
Return to Section TOC | Return to Master TOC | COMMANDER 400 | |
|
|