TROUBLESHOOTING & REPAIR

TOC

TOC

ABNORMAL SOLENOID PULL & HOLD COIL WAVEFORMS

Return to Section

Return to Master

 

 

 

 

TOC

TOC

 

 

 

 

Returnto Section

Returnto Master

SCOPE SETTINGS

SCOPE SETTINGS

 

 

1V

20 ms

200 MV

5 ms

 

 

Volts/Div

1V/Div.

Volts/Div

200 MV/Div.

 

 

Horizontal Sweep ...

20 ms/Div.

Horizontal Sweep

5 ms/Div.

 

 

Coupling

DC

Coupling

DC

 

 

Trigger

Internal

Trigger

Internal

TOC

TOC

The scope pictures above are exam-

Section

Master

ples of a short at the output of both

 

 

 

 

the pull and the hold coil circuits on

to

to

the control PC board. The overcur-

rent circuits in the pull and hold coil

Return

Return

circuits will shut down the circuit when

 

 

 

 

an overcurrent is sensed, preventing

 

 

damage to the circuit. The waveform

 

 

on the left will cause the solenoid to

 

 

not pull in. The waveform on the right

 

 

will cause the solenoid to pull in, then

 

 

drop out. Check for shorted solenoid

 

 

coils and grounded leads.

Return to Section TOC

Return to Master TOC

COMMANDER 400

 

 