Amana ART6002 Converting 3-Wire to 4-Wire Power Cord, Anti-tipBracket Installation, Level Range

Models: ARR6102 ARR6202 ART6002 ART6112

1 28
Download 28 pages 5.78 Kb
Page 9
Image 9
Converting 3-Wire to 4-Wire Power Cord

Converting 3-Wire to 4-Wire Power Cord

1.Remove rearwire cover.

2.Remove bottom strain relief screw and retain for further use.

3.Remove screw/hex nuts from terminal block and retain for further use.

4.Remove all 3-wire or cable leads from the terminal block and proceed to remove the power cord from the

range by pulling in a downward motion so the cord is removed from strain relief.

5.To install the 4-wire cord, please follow step 3

through step 9 of Installing 4-Wire Power Cord section.

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a properly installed anti-tip bracket.

1.Measure 31/2inches from back wall on right and left side of cabinet cutout. Mark measurements on floor

and draw a straight line connecting marks.

2.Position anti-tip bracket.

If range is installed beside cabinet(s), place anti-tip bracket with back edge on line drawn on floor and side of bracket against cabinet.

If range is not installed beside cabinet(s), position range where it will be installed. Draw a line along side of range on floor from front to back. Remove range. Place anti-tip bracket with back edge over line drawn 31/2inches from back wall and side of bracket over line drawn along side of range on floor.

Anti-tip bracket can be installed on either right or left side.

4.Drill 2 holes.

If drilling into wood, use a s/32-inchdrill bit.

If drilling into concrete, use a s/,c,-inchmasonry drill bit and insert plastic anchors.

5.Secure bracket to floor using screws supplied.

6.Slide range into position, remove range storage drawer or lower panel and confirm anti-tip bracket is engaged with range leveling leg.

Level Range

CAUTION

To avoid damaging oven door, do not lift or move range by oven door handle. Glass can break.

Carefully level range using legs provided. Range must be level to cook and bake uniformly.

Place a level on top oven rack or on range top when leveling.

Leveling legs must extended 1/4inch to engage anti-tip bracket.

Removal and Replacement of Range

1.Disconnect power to range.

2.Slide range forward.

3.Unplug range cord and place range aside.

4.Remove anti-tip bracket.

5.Install anti-tip bracket into new location using

instructions provided with bracket or see Anti-tip Bracket Installation section in this manual.

6.To reinstall range, follow instructions in Installation section of this manual.

?

or

\

Anti-tip Bracket Installation

3.Mark 2 hole locations in anti-tip bracket.

Page 9
Image 9
Amana ART6002, ART6112, ARR6202, ARR6102 Converting 3-Wire to 4-Wire Power Cord, Anti-tipBracket Installation, Level Range