Irregular Cabinet and Countertop Heights

Countertops such as ceramic tile tops cause cabinet and countertop to be higher than 36 inches. Follow instructions below when countertop is higher than 36 inches.

1.Raise leveling legs to maximum height.

2.Measure from floor to rangetop. If measurement is

less than height of countertop, floor must be shimmed.

3.Shim floor using a piece of plywood same size as range opening. Secure plywood to floor. Plywood must be as secure as original flooring.

4.Install anti-tip bracket and slide range into place.

Line Voltage Requirements

Line voltage must not exceed rated voltage. See rating plate attached to range for kilowatt rating. Line voltage less than rated voltage will result in slow heating. Wiring system must conform to Underwriters Laboratories, Inc. standards and National Electrical Code. Installation must conform to all

local, municipal and state building codes, and local utility regulations. Range must be connected only to a supply circuit as specified on rating plate wiring diagram of range.

Range requires 3 wires, 120/240 Volts 60 Hertz A.C. House wiring and fusing must comply with local wiring

codes. If no codes apply, wire according to National Electrical Codes.

Power Cord Requirements

Power cord is not supplied with range. Power cord must be U.L. Listed and meet NEC and Mobile Home

Manufacturers Association Standards. Cord must be rated at a minimum 250V_40 AMP, equipped with a plug configuration in accordance with NEMA. Conductors must end with closed loop (ring) terminals at the range.

Three-conductor cord plug NEMA 10-50P allowed for residential.

Four-conductor cord plug NEMA 14-50P required for most mobile home installations but can be used for

residential.

NOTE: Only a power cord suitable for use with ranges may be used. For installation in a mobile home, or area where local codes do not permit grounding through the neutral terminal, a 4-wire cord must be used.

Range Terminal Block

Connection block is located at bottom rear of range behind rear cover panel. Remove rear cover screw. Directly below terminal block is a hole for a power supply service cord. Power cord is not supplied with range.

Power Supply Location

Shaded area show range clearance for electrical connection.

Attach Power Cord

A3 inches

B7 inches

C6 inches

D30I/8 inches mininmm _24_/16

Power Supply Location

Page 6
Image 6
Amana ARR6202, ART6112 Irregular Cabinet and Countertop Heights, Line Voltage Requirements, Power Cord Requirements