Amana ART6002 Installation, iCAUTION, Packing Material, Range Location, Cabinet Opening, Iwarning

Models: ARR6102 ARR6202 ART6002 ART6112

1 28
Download 28 pages 5.78 Kb
Page 5
Image 5
Installation

Installation

Packing Material

Remove protective packing materials from range. Tape residue can be cleaned with a soft cloth and alcohol.

Range Location

Underwriter's Laboratories, Inc. specifies range can be installed flush against right and left base cabinets, and rear vertical wall. Range can also be installed flush against left or right vertical wall extending above 36 inch standard countertop height.

Cabinet Opening
IWARNING ]

To avoid risk of burns or fire by reaching over elements, cabinet storage space located above range should be avoided. If cabinet storage is provided, install a range hood that projects horizontally a minimum of 5 inches beyond the cabinet bottom to reduce the risk.

Minimum Clearances to Combustible Surfaces

Using dimensions, prepare cabinet opening.

Minimum clearance to rear wall is 0 inches.

Minimum clearance to a vertical right or left side wall is 0 inches.

Minimum clearance to countertop/cabinet on each side is 0 inches.

Minimum of 30 inches between top of cooking surface and bottom of an unprotected wood or metal cabinet.

Minimum of 24 inches between cooking surface and protected wood or metal cabinet above range. Cabinet bottom must be protected by at least 1/4inch thick millboard with not less than No. 28 MSG sheet steel,

.015 inch thick stainless steel, .024 inch thick aluminum, or .020 inch thick copper.

iCAUTION ]

Do not store items of interest to children in cabinets above a range or behind the backguard of a range. Children climbing on the range to reach items could be seriously injured.

Range should extend approximately 2 inches from cabinet front to oven door handle. Using dimensions, prepare cabinet opening.

l

c

 

A

30

inches

minimum

 

 

B

30

inches

unprotected/24

inches protected minimum

 

C

13

inches

maximum

 

 

D

25

inches

maximum

 

,s,, "'S

_36

 

inches

maxinmm

 

 

 

 

_301/8 to 301/4inches

B36inches standard

C35 inches standard

D23 inches standard

E25 inches standard

Minimum Clearances to Combustible Surl_aces

Standard Cabinet and Countertop

Height

5

Page 5