Installation Instructions for MAP7 Commercial Recessed Housing with Compact Electronic Ballast

Junction Box Cover

Housing

Ballast

Junction Box

Mounting Channels

(Portfolio HB26, HB50

Accessories or

Furnished by Others.)

Plaster Ring

CAUTION: To avoid possible electrical shock, be sure that power supply is turned off before installing or servicing this fixture.

Note: This fixture should be supported by main runners or other structure that is capable of supporting fixture weight of 35 lbs.

Step 1 Suggested tools are a non-magnetized flat head screwdriver or needle nose pliers.

Step 2 To Install Fixture: Using standard bar hangers, C-Channels (available through Portfolio or furnished by others), 3/4" and 1 1/2" lathing or 1/2" conduit (all supplied by others), insert through the universal hanger brackets and secure the mounting bars or channels to the ceiling structure so that the edge of the die cast mounting frame is flush with the finished ceiling.

Step 3 Push lampholder into a regressed position (Fig. 1).

FIG 1

Push lampholder into a regressed position

FIG 2

 

Elongated

 

 

Slot in

 

 

Can

 

White

 

Ceiling

Trim

Black

Ring

Baffle

 

 

Step 4

To Install Trim: With screw driver or needle nose pliers, stretch baffle

WIRING DIAGRAM

 

 

 

 

 

 

 

mounting spring, then hook into elongated slot in the housing

 

 

 

 

 

 

 

 

(Fig. 2).

BLACK INPUT

 

BLACK

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE/RED

INSULATION

 

 

 

Step 5

Pull lampholder down and adjust to desired position.

 

 

 

 

 

 

 

 

 

DETECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE - 120V

 

 

 

CAUTION: Use with ceramic metal halide lamps approved for use in open

WHITE (COMMON)

 

 

RED - 277V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixtures. Do not use an incandescent lamp as this may cause

 

 

WHITE

 

 

 

 

extremely short lamp life and may damage the ballast.

 

 

BLACK

 

 

 

 

 

 

ELECTRONIC

BLUE / RED

 

 

 

 

 

 

BALLAST

 

BLUE

 

 

 

 

NOTE: The electronic ballast has a very improtant "shutdown" timing

 

 

 

 

 

 

 

 

GREEN

BLACK

 

 

 

 

 

 

 

 

 

feature that turns off the ballast output after time periods ranging from 2

 

 

 

LAMP

 

 

 

minutes up to 30 minutes if a lamp does not start or operate properly or if

 

 

 

 

 

 

 

the fixture wiring is improper. For proper system diagnosis and at lamp

 

 

 

WHITE

 

 

 

replacement time; the INPUT POWER TO THE BALLAST MUST BE RESET

 

 

 

 

 

 

 

(turn power off, count to 10, and then turn bqack on) to start a new lamp.

 

 

 

 

 