Installation Instructions
Sheet 1 of 2
Vault |
Roundel |
Small, INDOOR
P4R
(Pendant,
Visor and Non-Visor
Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not
These installation instructions are valid with the above Ametrix styles.
mount fixtures vertically.
Exploded view and part
1Mounting pendant to
1/4" Fastener (4x)
Canopy
Cover plate
(by others)
| |
1/4" fasteners | (by others) |
(by others) |
|
(4x) | Use additional bracing |
| |
| around |
| fixture. |
| |
Set screw |
|
(2x) | Canopy |
| |
Cover plate |
|
| |
| Hex cap bolts |
| (4x) |
Attention:
Quad fixture assemblies require additional bracing/structure
around
1.Remove all
2.Remove both
3.Run wires from
4.Using appropriate fasteners, secure fixture to ceiling. Use additional bracing around
5. Replace canopy and secure using both set screws.
2Wiring the fixture
Fixture wire | |
Hex cap bolts |
|
(4x) |
|
| Cover plate |
1.With pendant secure, slide fixture assembly onto pendant and secure with four
2.Remove cover plate and insert wires from fixture heads into pendant and pull through opening.
3.Attach appropriate wires and ensure all connections are properly matched.
4.Push connections into pendant and secure cover plate.
3Aiming the fixture
Fixture head indicator
Yoke arm indicator
1.To aim fixtures, loosen both
2.When fixture head is rotated to the desired angle, retighten end screws to secure the position.
3.Repeat for remaining fixture heads.
ADY071466 REV B(ECN80481)