PHOTOMETRICS

PHOTOMETRICS

DIM

 

 

DIM-396HO

Energy Saving Ballast

DIM-396HO

Energy Saving Ballast

F96T12/CW/HO/WM Lamps

8000 Lumens Spacing criterion:

(II)1.3 x mounting height, () 1.4 x mounting height

Efficiency 87.4%

Test Report: DIM396HO.IES

LER = FI-55

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $4.36

ORDERING INFORMATION

C o e f ficients of Utilization

 

 

Effective floor cavity reflectance

 

 

20%

 

 

 

 

 

 

 

 

 

rc

 

80%

 

 

70%

 

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

101

101

101

101

97

97

97

97

90

90

90

83

83

83

77

77

77

74

 

1

92

87

84

80

88

84

81

78

78

75

73

72

70

68

67

65

64

61

 

2

83

76

70

65

79

73

67

63

68

63

59

63

59

56

58

55

53

50

 

3

75

66

59

53

72

64

57

52

59

54

49

55

50

47

54

17

44

42

 

4

69

58

50

45

66

56

49

43

52

43

41

49

44

39

45

41

38

35

 

5

63

52

44

38

60

50

43

37

47

40

35

43

38

34

40

36

32

30

 

6

58

46

38

33

55

45

37

32

42

35

31

39

34

29

36

32

28

26

 

7

54

42

34

29

51

40

33

28

38

32

27

35

30

26

33

28

25

23

 

8

50

38

30

25

48

37

30

25

34

28

24

32

27

23

30

26

22

20

 

9

46

35

27

23

44

34

27

22

32

26

21

30

24

21

28

23

20

18

 

10

43

32

25

20

42

31

24

20

29

23

19

27

22

19

26

21

18

16

Zonal Lumen Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Fixture

0-30

4303

17.9

20.5

0-40

7221

30.1

34.4

0-60

13537

56.4

64.6

0-90

17747

73.9

84.6

90-180

3219

13.4

15.4

0-180

20967

87.4

100.0

C a n d e l a

Angle

Along II

45o

Across

0

5322

5322

5322

10

5288

5277

5335

20

5034

5150

5265

30

4619

4869

5042

40

4057

4453

4734

50

3325

3911

4195

60

2517

3114

3264

70

1563

2071

1955

80

616

720

485

90

21

70

71

100

96

195

176

110

300

405

452

120

524

311

533

130

733

516

406

140

919

770

630

150

1065

910

883

160

1170

1150

1046

170

1226

1222

1242

180

1243

1243

1243

S A M P L E N U M B E R : D I M - 3 9 6 H O - 1 2 0 V- E B 8 1- U

Tandem

Blank=4' Length

8T=8' Length

Series

DIM=

Apertured

Reflector

DCIM=

Closed Top

Reflector

Lamp Spacing

Blank=Standard Spacing

N=Narrow Spacing for 2 Lamp Only (10% uplight)

Number

of Lamps

3Lamps

(Not included)

Wattage (Length)

96HO=95/110W T12 (96") HO 96HO=86W T8 (96") HO

Voltage (1)

120V=120 Volt

277V=277 Volt

347V=347 Volt

Options

BallastType (1)

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB8 /PLUS=T8 Electronic Instant Start.

 

 

 

 

High Ballast Factor >1.13.Total

No. of

Harmonic Distortion < 20%

Ballast

 

1, 2 or 3

 

ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB2 =T12 Electronic Rapid Start.

Options

RIF1=Radio Interference Suppressor

6-3/18 SJT-C&P-515P=Cord

& Plug (120V)

6-3/18 SJT-C&P-

L715P=Cord & Plug (277V)

PI/CPI=Plug-In Option

TILW=Tandem In-Line

Wiring Option (Consult

TILW Option Catalog Page)

POX=Porlux Finish

(See options & accessories)

Packaging

U=Unit Pack

4B=4 Bulk

GL=Single Element Fuse

GM=Double Element Fuse

Emergency=EM Installed

No. of Ballast 1 or 2

NOTES: (1)Products also available in non-US voltages and frequencies for interna- tional markets.

Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

SHIPPING INFORMATION

Catalog No.

Wt.

 

DIM-396T8HO

40 lbs.

 

 

 

 

ACCESSORIES

(Order Separately)

A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture)

ATG-4=Tong Hanger (Use 2 per fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48" Stem Set

AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture) WG/DI-4FT-U2=Wire Guard

WGG/DI-4FT-U2=Wire Gym Guard MECL-DI/SL-48-U=Metal Egg Crate Louver MECL-DI/SL-96-U=Metal Egg Crate Louver DI2=Long Connector

CEP=Closed End Plate

(Additional Accessories Available. See Options and Accessories Section).

Specifications and Dimensions subject to change without notice.

ADF020753

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

09/17/2008 2:07:11 PM

Page 2
Image 2
Cooper Lighting P4S8X-MX DIM-396HO, Energy Saving Ballast F96T12/CW/HO/WM Lamps, Lumens Spacing criterion, Photometrics