Cooper Lighting SCH dimensions Fail-Safe, Scg Sch, Cleanroom, 3 4 W - 1 6 0 W, Cooper Lighting

Models: SCH SCG

1 1
Download 1 pages 43.61 Kb
Page 1
Image 1
CLEANROOM

CLEANROOM

 

FAIL-SAFE®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D E S C R I P T I O ND I M E N S I O N S

SCG

SCH

3 4 W - 1 6 0 W

F l u o r e s c e n t

1 ' x 2 ' , 1 ' x 4 ' , 2 ' x 2 ' , 2 ' x 4 '

S P E C I F I C AT I O N G R A D E F L U O R E S C E N T G R I D

1 " , 1 - 1 / 2 " o r 2 " G r i d

• Lens is clear extruded with

prisms positioned inside

fixture and smooth surface

on the outside for easy

cleaning

• Flush mounted, stainless

steel machine screws

• Nominal 4-1/4" (SCG24) or

5" (SCG12/SCH24) deep

recessed one-piece 20 ga.

CRS housing

The Fail-Safe SCG12, SCG24 and SCH24 Series are designed for use in horizontal or non- laminar air flow clean rooms and features the added convenience of field retrofitting for flange or grid installations.The enclosed and gasketed housing and door protect against infiltration of airborne bacteria. Fixtures tested to 100 PSI hose down. Higher ratings available (consult factory). The mitered edges on the door frame and the hole-free design of the housing prevent air exchange between the fixture and plenum, allowing relamping without contamination of the clean areas. An emergency battery pack is available as an option. Fixtures are U.L. listed and C.S.A. standard wet label. These luminaires are manufactured in accordance with U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E. The SCG12 Series is suitable for use in I.E.S. Class 10 (M2.5), 100 (M 3.5), 1,000 (M 4.5), 10,000 (M 5.5) and 100,000 (M 6.5) clean room environments.

O R D E R I N G I N F O R M AT I O N

 

 

 

 

A

 

 

 

 

A

 

 

 

BB

 

M O U N T I N G

 

 

D O O R F R A M E

 

 

 

B

 

 

 

 

 

Extruded aluminum

 

C

 

 

mitered door frame and

 

 

 

 

housing trim flange with

 

 

 

 

extruded silicone rubber

 

 

 

 

perimeter gasketing

 

A

B

 

C

SCG12

5"

11

11/16"

24"

1'x 2'

(127mm)

(297mm)

(610mm)

SCG12

5"

11

11/16"

48"

1'x 4'

(127mm)

(297mm)

(1219mm)

SCG24

4 1/4"

23

11/16"

24"

2'x 2'

(108mm)

(602mm)

(610mm)

SCG24

4 1/4"

23

11/16"

48"

2'x 4'

(108mm)

(602mm)

(1219mm)

SCH24

5"

23

3/16"

24"

2'x 2'

(127mm)

(589mm)

(610mm)

SCH24

5"

23

3/16"

48"

2'x 4'

(127mm

(589mm)

(1219mm)

One piece stainless steel door frame and housing trim flange with extruded closed cell silicone perimeter gasketing

S A M P L E N U M B E R : S C G - 2 4 - 3 4 0 - 2 7 7 - I K 1 2 - L E 3 - A L P - G L R

Unique, Particulock™ lens

 

retention system. Lens is

 

hermetically sealed to door

 

frame

Optional extruded

 

aluminum, mitered, fully

 

gasketed, outside flanged

 

door; or one-piece, die-

 

formed stainless steel door

• Standard Class P, CBM/ETL

 

ballast

MicroSealTM gasketing

 

system features silicone

 

RTV sealant sealing lens to

 

door frame and extruded

 

silicone rubber gasketing

 

seals door to ceiling. White,

 

closed cell Flexiseal™ seals

 

fixture to ceiling

• Gasketed access plate with

 

two flattened, 7/8" diameter

 

knockouts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series

Width

 

Voltage

 

SCG=Specification

12=12"

 

 

 

120=120V

 

Grade

24=24"

 

 

 

277=277V

 

 

 

 

 

 

 

Cleanroom Grid

 

 

 

 

 

347=347V

 

Type

 

 

 

 

 

UNV=120V

 

SCH=Specification

 

 

 

 

 

 

through

 

 

 

 

 

 

 

 

Grade

 

 

 

 

 

 

277V

 

Cleanroom

 

 

 

 

 

 

 

 

 

Heavy Grid Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

Biaxial Fluorescents

 

24" Fixture Length

 

140BX=(1) 40W Lamp

 

T8 Fluorescents

 

240BX=(2) 40W Lamps

 

117=(1) 17W Lamp

 

340BX=(3) 40W Lamps

 

217=(2) 17W Lamps

 

48" Fixture Length

 

317=(3) 17W Lamps

 

 

417=(4) 17W Lamps

 

T8 Fluorescents

 

 

 

 

 

 

132=(1) 32W Lamp

 

T12 Fluorescents

 

232=(2) 32W Lamps

 

120=(1) 20W Lamp

 

332=(3) 32W Lamps

 

220=(2) 20W Lamps

 

432=(4) 32W Lamps

 

320=(3) 20W Lamps

 

 

 

 

 

 

 

 

420=(4) 20W Lamps

T12 Fluorescents

140=(1) 40W Lamp

 

U Lamps*

240=(2) 40W Lamps

340=(3) 40W Lamps

2U 1 5/8=(2)31W T8

440=(4) 40W Lamps

Lamps

 

3U 1 5/8=(3) 31WT8

 

Lamps

 

2U6T8=(2) 32WT8 Lamps

 

2U6=(2)40WT12Lamps

 

Lens Type

IK12=K-12 Prismatic Acrylic

IP12=K-12 Prismatic Polycarbon ate

KSH251=Bat Wing Distributi on

93=Prismatic Tempered Glass

Ballast

LE3=Energy

Saving

Ballast

Electronic

Ballast2

EB81=(1) Ballast

for use

with T8

Lamp

EB82=(2) Ballasts

for use

with T8

Lamp

EB21=(1) Ballast

for use

with T12

Lamp

EB22=(2) Ballasts

for use

with

T12Lamp

EBX1=(1) Ballast

for use

with

Biaxial

Lamp

EBX2=(2) Ballasts

for use

with

Biaxial

Lamp

Door/Finish Options

Options

ALP=Aluminum

EBP=Emergency

Door & Trim,

Battery Pack

Polyester

GLR=Fuse and

Powder Finish

Holder

ALX=Extruded

RIF=Radio Frequency

Aluminum

Interference

Door & Trim,

Filter

Clear Anodized

Housing Options

Finish

SHN=Stainless Steel,

ALXP=Extruded

Brushed 304

Aluminum

Finish

Door & Trim,

SHP=Stainless Steel,

Polyester

Polyester

Powder

Powder Finish

Finish

 

(Standard)

ALH=Aluminum,

 

Polyester

 

Powder Finish

1488 COOPER LIGHTING

Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.

1The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.

2 For specific electronic ballast, specify brand and catalog number.

Page 1
Image 1
Cooper Lighting SCH, SCG dimensions Fail-Safe, Scg Sch, Cleanroom, 3 4 W - 1 6 0 W, Cooper Lighting