CARE AND MAINTENANCE
Maintenance Schedule
The following schedule should be followed to insure your appliance stays in peak condition.
Weekly Maintenance: The following should be done once a week:
ASH DISPOSAL
CLEANING OF GOLD PLATED SURFACES
GLASS CLEANING
DOOR AND WINDOW GASKET INSPECTION
LUBRICATE
DOOR LATCH INSPECTION AND ADJUSTMENT
CHECK FOR CREOSOTE
Yearly Maintenance: The following should be done after each heating season:
CATALYTIC COMBUSTOR INSPECTION & CLEANING
FIREBOX INSPECTION AND CLEANING
APPLIANCE
BLOWER CLEANING
CHIMNEY SYSTEM CLEANING
Maintenance Instructions
ASH DISPOSAL
During constant periods of use ashes must be periodically removed from the appliance to prevent a
CLEANING OF GOLD PLATED SURFACES
Gold is the very best material available for plating fireplace fronts, but it is not indestructible. The most common complaint with any plated surface on a wood burning appliance is discoloration. This can only be caused by heat and chemicals. The discoloration is permanent and cannot be removed without removing the gold plating. The following suggestions will help you keep the shine in your gold plating.
Keep plating free of dust and finger prints with DENATURED ALCOHOL applied with a very soft cloth. Do not use any other cleaners or polishes. Do not start a fire if there are finger prints or smudges on the gold plating, as they could become permanently etched in the gold plating. Make sure that the brick or stone is free of acid before installing the gold plating, consult your mason.
Denatured |
A l c o h o l |
Page 17