COOPER LIGHTING - SURE-LITES®
D E S C R I P T I O N
The StairLite System is designed to satisfy all stairwell lighting requirements in one easy to install package. StairLite consists of a surface mounted, two lamp fluorescent lighting fixture that incorporates an integrally mounted ultrasonic motion detector, a system display panel, and an optional full battery backup. The StairLite System will deliver vastly reduced operating and maintenance costs due to virtually no power consumption. It will enhance the usefulness, safety, and reliability of any emergency lighting system. The StairLite System is designed for use in stairwells or any other area of a building where the occupancy level or usage factor would be considered minimal.
D I M E N S I O N S
2 1/8" [54mm]
1 5/8" [41mm]
10"
[254mm]
A
Lamp | Dimension “A” |
|
|
|
|
| |||||
FO17T8 | 27" (686mm) |
|
|
|
|
| |||||
FO25T8 | 39" (991mm) |
|
|
|
|
| |||||
FO32T8 | 51" (1295mm) |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STL STAIRLITE
S t a i r w e l l L i g h t i n g
S y s t e m
E M E R G E N C Y L I G H T
• Choice of Input Voltage, |
120 or 277 VAC, 60Hz |
• Formed 20 gauge steel |
housing and cover plate |
construction |
• Durable white powder coat |
finish |
• T8 Fluorescent lamps in 17, |
25 and 32 watts (Lamps not |
included) |
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : S T L 4 2 F 1 7
• |
ballast that is “0” Degree |
EMERGENCY LIGHTS Architectural
STL
Family
STL=StairLite
Operation
4=AC Only
54=Emergency
450Lumens 57=Emergency
700Lumens 59=Emergency
950Lumens
Lamp
2F17=(2) FO17T8 (2' lamps)
2F25=(2) FO25T8 (3' lamps)
2F32=(2) FO32T8 (4' lamps)
Voltage
Blank=120 VAC 7=277 VAC
Accessories (Order
Separately)
VRSPD=#6 Spanner
Screw Driver
rated |
• Sealed, |
nickel cadmium battery |
• Fully automatic, |
ultrasonic motion detector |
• |
Display System with an AC |
power indicator |
• Fully automatic emergency |
charger is |
mechanical relay |
• Variety of electrical and |
mounting knockouts for a |
easy installation |
• |
Head Screws, Standard |
E n e r g y D a t a
| Input Power; | Input Current (Max.): | Power Factor: | |||
| 120V | 277V | 120V | 277V | 120V | 277V |
(2) 17W T8 | 31W | 31W | .29A | .13A | .8 | .8 |
(2) 25W T8 | 42W | 42W | .36A | .16A | .8 | .8 |
(2) 32W T8 | 52W | 52W | .44A | .19A | .9 | .9 |
Lamps Off | 4.3W | 4.3W | .04A | .02A | .7 | .7 |
• UL 924, Life Safety NFPA |
101, NEC/OSHA, most state |
and local codes |
COOPER LIGHTING
613