Image 2
PERFORMANCE

TF28

PERFORMANCE

MAINTENANCE

 

 

 

PHOTOMETRICS

Candlepower Distribution

4522

180

3391

 

2261

 

1130

 

90

90

Candlepower

Deg.

0

4522

4522

5

4510

4464

15

4002

4106

25

3294

3421

35

2648

2779

45

1992

2129

55

1401

1475

65

840

904

75

365

385

85

50

44

90

0

0

Zonal Lumen Summary

Zone

Lumens

%Lamp

%Luminaire

0-30

3117

26.0

34.3

0-40

4818

40.2

53.0

0-60

7716

64.3

84.9

0-90

9091

75.8

100.0

90-180

0

0.0

0.0

0-180

9091

75.8

100.0

Test No. TF28150ICE24093

Lamp= 150W Icetron™

Lumens= 12,000

Efficiency= 75.8%

Coefficient of Utilization

rc

 

 

80%

 

 

70%

 

 

50%

 

30%

 

10%

0%

rw

 

70

50

30

10

50

30

10

50

10

50

10

50

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

90

90

90

90

88

88

88

84

84

81

81

77

77

77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

83

80

77

75

78

76

73

75

71

72

69

70

67

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

76

71

66

62

69

65

61

67

60

64

59

62

57

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

70

63

57

53

62

57

52

60

51

58

50

56

50

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

65

56

50

45

55

50

45

54

45

52

44

50

43

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

60

51

44

40

50

44

40

48

39

47

39

46

38

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

56

46

40

35

45

39

35

44

35

43

34

42

34

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

52

42

36

31

41

36

31

40

31

39

31

38

31

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

48

39

33

28

38

32

28

37

28

36

28

35

28

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

45

36

30

26

35

30

26

34

26

34

25

33

25

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

43

33

27

24

33

27

23

32

23

31

23

31

23

22

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

Specifications and Dimensions subject to change without notice.

ADC041739

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/10/2007 9:39:52 AM

Page 2
Image 2
Cooper Lighting TF28 specifications Performance, Maintenance, Photometrics, Candlepower Distribution, Zonal Lumen Summary