Tandberg Data FS-1600, FS-1610 Front Panel LED Indicators, Power Supply Unit Failure LED

Models: FS-1600 FS-1610

1 53
Download 53 pages 22.07 Kb
Page 9
Image 9
7.Power Supply Unit Failure LED

Tandberg DataOverview

_____________________________________________________________

7.Power Supply Unit Failure LED

Indicates if one or more power supply units have failed.

1.4.Front Panel LED Indicators

LED

Colour

State

Meaning

 

 

 

 

Power

Green

On

FS-1600 Series NAS is on.

 

 

Off

FS-1600 Series NAS is off.

HDD

Green

Off

No hard-drive activity or no hard-drive is

 

 

 

connected or.

 

 

Blink

Hard-drive activity.

HDD (Fault)

Amber

On

Hard-drive is faulty.

 

 

Off

Hard-drive is in normal state.

LAN

Green

On

Network link is established.

 

 

Blink

Network link is established and LAN

 

 

 

activity.

 

 

Off

No link is established and cable could be

 

 

 

faulty.

Over Temp

Red

On

FS-1600 Series is overheated.

 

 

Off

FS-1600 Series is in normal condition.

 

 

Blink

One or more the system fans failure.

Power Fault

Red

On

One or more PSU have failed.

 

 

Off

All PSU is in normal conditions.

 

 

 

 

1-5

Tandberg Viking FS-1600 Series NAS Hardware User Manual

Page 9
Image 9
Tandberg Data FS-1600, FS-1610 user manual Front Panel LED Indicators, Power Supply Unit Failure LED, Tandberg DataOverview