Tandberg DataSystem Management
_____________________________________________________________
5.2.RAID Management
The RAID volume of
5.2.1.Configure and Creation of RAID Volumes
The RAID BIOS Configuration Utility is used to create or configure the hardware RAID of
Notes
The RAID BIOS is accessed by pressing TAB / F6 key during boot. The default BIOS password is “0000” when prompted.
Before restoring the factory default image to Viking
1.During the boot process, depress TAB / F6 key to enter the RAID BIOS.
2.Create RAID set that comprises of the physical member HDD. If you have 4 HDD, you can select all 4 HDD into a RAID set.
3.Create the Volume set (SV) within the RAID set. Decide the RAID level and strip size of SV and the desire capacity.
Notes
It is recommended that the minimum capacity of the System Volume is set to 10GB and RAID level 0+1 for OS redundancy. Tandberg Data does not recommend setting the capacity value of SV below 10GB.
4.Enter the default password word if prompted.
5.The system will start performing the RAID volume creation. Depending on the capacity of the SV selected as well as its RAID level, this process may take several hours to complete. Once completed, the appliance has to be rebooted for the volume to take effect.
Tandberg Viking |