Trouble

 

Probable Cause

BEVERAGE NOT SWEET ENOUGH.

A.

Empty syrup tank.

 

B.

Faucet brix requires adjusting.

 

 

 

BEVERAGES NOT COLD (UNITS WITH BUILT–IN

A.

Unit standing with no ice in hopper – no ice in

COLD PLATE).

 

cold plate cabinet.

 

 

 

AGITATORS TURN IN OPPOSITE DIRECTIONS

A.

This is normal and is necessary for uniform ice

 

 

agitation.

 

 

 

ICE DOES NOT DISPENSE FROM ONE GATE

A.

Agitators reversed

ASSEMBLY

B.

Defective gate solenoid or rectifier

 

 

C.

Motors wired incorrectly

 

 

 

FLAVOR SYRUPS DO NOT DISPENSE

A.

No 24 volt power to PC board.

 

B.

No CO2 pressure.

 

C.

Empty syrup tank.

 

D.

Kinked tubing.

 

E.

Clogged inner nozzle.

 

F.

Defective PC board.

 

G.

Defective harness from keypad.

 

H.

Defective Flow control.

 

I.

Defective solenoid harness.

 

J.

Defective keypad.

 

 

 

FLAVOR DISPENSES FOR MORE THAN 1 SEC

A.

Dip switch settings on control board incorrect.

 

B.

PC board defective.

 

C.

Defective flow control.

 

 

 

FLAVOR DISPENSES MORE THAN .5 OZ

A.

Dip switch settings on control board incorrect.

 

B.

Flow control incorrectly set.

 

C.

PC board defective.

 

D.

Defective flow control.

Contact your local syrup or beverage equipment distributor for additional information and troubleshoot- ing of beverage system.