REMOVAL AND REPLACEMENT OF AGITATORS

Agitator Disk, L.H., With Center Hole

Thumb Screw

Left

Front View

Valve Side

Top of Dispenser

92089

TO REMOVE LEFT, CCW AGITATOR

Agitator Disk, R.H., With 2

Retain

1.Remove center thumb screw by turning it counterclockwise.

2.Lift plastic agitator disk off of stainless steel agitator.

3.Grip agitation arms at the center and lift up.

4.Replace by reversing steps.

TO REMOVE RIGHT, CW AGITATOR

1.Remove the (2) retaining pins.

2.Lift plastic agitator disk off of stainless steel agitator.

3.Grip agitation arms at the center and lift up.

4.Replace by reversing steps.

Note: Refer to Sanitize Procedure in the Owners Instruction for complete cleaning and sanitizing instructions.